Endoscopic ultrasound in diagnosis of solid pancreatic lesions: Elastography or contrast-enhanced harmonic alone versus the combination

نویسندگان

  • Tanyaporn Chantarojanasiri
  • Yoshiki Hirooka
  • Hiroki Kawashima
  • Eizaburo Ohno
  • Takamichi Kuwahara
  • Takeshi Yamamura
  • Kohei Funasaka
  • Masanao Nakamura
  • Ryoji Miyahara
  • Masatoshi Ishigami
  • Osamu Watanabe
  • Senju Hashimoto
  • Akihiro Hirakawa
  • Thawee Ratanachu-ek
  • Hidemi Goto
چکیده

Background and study aims  Endoscopic ultrasound (EUS) elastography (EUS-E) and contrast-enhanced harmonic EUS (CH-EUS) are useful methods for the diagnosis of pancreatic lesions. This study aims to compare the accuracy of combined EUS-E and CH-EUS with that of EUS-E or CH-EUS alone in the differential diagnosis of pancreatic solid lesions. Patients and methods  One hundred thirty-six patients with solid pancreatic lesions underwent EUS with both EUS-E and CH-EUS were included. Diagnoses were classified as adenocarcinoma, neuroendocrine tumor (NET), and inflammatory pseudotumor in 95, 22, and 19 patients, respectively. EUS records in each case were rearranged into 3 groups: EUS-E, CH-EUS, and combination. Each modality was randomly reviewed by 3 reviewers with different levels of clinical experience. Sensitivity, specificity, and accuracy of each modality according to each diagnosis group were evaluated. For the combined diagnosis populations, the proportions of correct diagnoses among the 3 modalities were compared by using the multivariate logistic regression analysis. Results The accuracies of EUS-E, CH-EUS, and the combination of them were 68.4 %, 65.4 %, and 75.7 %, respectively, for adenocarcinoma group; 83.8 %, 82.4 %, and 86.8 % for NET group; 80.1 %, 78.7 %, and 81.6 % for inflammatory pseudotumor group. The multivariate logistic regression analysis for the combined diagnosis populations showed that the proportion of correct diagnoses when EUS-E and CH-EUS were combined was slightly higher than with the other 2 modalities, although the significant differences among them were not observed. Conclusion EUS-E and CH-EUS combined may improve differential diagnosis of solid pancreatic lesions compared with use of the individual modalities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrast-Enhanced Harmonic Endoscopic Ultrasound-Guided Fine-Needle Aspiration in the Diagnosis of Solid Pancreatic Lesions: A Retrospective Study

BACKGROUND The negative predictive value of endoscopic ultrasonography-guided fine needle aspiration for the diagnosis of solid pancreatic lesions remains low, and the biopsy specimens are sometimes inadequate for appropriate pathological diagnosis. AIMS To evaluate the usefulness of a novel method of contrast-enhanced harmonic endoscopic ultrasonography-guided fine-needle aspiration for the ...

متن کامل

Clinical Role of Contrast-Enhanced Harmonic Endoscopic Ultrasound in Differentiating Solid Lesions of the Pancreas: A Single-Center Experience in Korea

BACKGROUND/AIMS The differential diagnosis of pancreatic solid lesions remains challenging. The aim of this study was to investigate the accuracy of contrast-enhanced harmonic endoscopic ultrasound (CEH-EUS) in differentiating pancreatic cancer from benign lesions. METHODS We prospectively evaluated 37 patients with pancreatic solid lesions. After intravenous injection of a contrast agent (So...

متن کامل

Contrast-enhanced Harmonic Endoscopic Ultrasound in Differentiating Solid Lesions of Pancreas

Background/Aims: The differential diagnosis of pancreatic solid lesions still remains challenging. Recently, contrast-enhanced harmonic endoscopic ultrasound (CE-EUS) has been developed. The aim of this study is to investigate the accuracy of CEEUS in differentiating pancreatic cancer from benign pancreatic lesions by visualizing pancreatic microvasculature. Method: We prospectively evaluated 1...

متن کامل

New endoscopic ultrasonography techniques for pancreaticobiliary diseases

Endoscopic ultrasonography (EUS) is widely used to evaluate pancreaticobiliary diseases, especially pancreatic masses. EUS has a good ability to detect pancreatic masses, but it is not sufficient for the differential diagnosis of various types of lesions. In order to address the limitations of EUS, new techniques have been developed to improve the characterization of the lesions detected by EUS...

متن کامل

Endosonography in solid and cystic pancreatic tumors.

Pancreatic tumors being either benign or malignant can be solid or cystic. Although diverse in presentation, their imaging features share commonalities and it is often difficult to distinguish these tumors. Endoscopic ultrasonography (EUS) is the most sensitive of the imaging procedures currently available for characterizing pancreatic tumors, and is especially good in identifying the smaller s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017