Cone-beam computed tomography with a flat-panel imager: initial performance characterization.
نویسندگان
چکیده
The development and performance of a system for x-ray cone-beam computed tomography (CBCT) using an indirect-detection flat-panel imager (FPI) is presented. Developed as a bench-top prototype for initial investigation of FPI-based CBCT for bone and soft-tissue localization in radiotherapy, the system provides fully three-dimensional volumetric image data from projections acquired during a single rotation. The system employs a 512 x 512 active matrix of a-Si:H thin-film transistors and photodiodes in combination with a luminescent phosphor. Tomographic imaging performance is quantified in terms of response uniformity, response linearity, voxel noise, noise-power spectrum (NPS), and modulation transfer function (MTF), each in comparison to the performance measured on a conventional CT scanner. For the geometry employed and the objects considered, response is uniform to within 2% and linear within 1%. Voxel noise, at a level of approximately 20 HU, is comparable to the conventional CT scanner. NPS and MTF results highlight the frequency-dependent transfer characteristics, confirming that the CBCT system can provide high spatial resolution and does not suffer greatly from additive noise levels. For larger objects and/or low exposures, additive noise levels must be reduced to maintain high performance. Imaging studies of a low-contrast phantom and a small animal (a euthanized rat) qualitatively demonstrate excellent soft-tissue visibility and high spatial resolution. Image quality appears comparable or superior to that of the conventional scanner. These quantitative and qualitative results clearly demonstrate the potential of CBCT systems based upon flat-panel imagers. Advances in FPI technology (e.g., improved x-ray converters and enhanced electronics) are anticipated to allow high-performance FPI-based CBCT for medical imaging. General and specific requirements of kilovoltage CBCT systems are discussed, and the applicability of FPI-based CBCT systems to tomographic localization and image-guidance for radiotherapy is considered.
منابع مشابه
Cone-Beam CT with a Flat-Panel Imager: Noise Considerations for Fully 3-D Computed Tomography
Application of flat-panel imagers (FPIs) in cone-beam computed tomography (CBCT) offers a promising new modality for fully three-dimensional (3-D) x-ray imaging. Understanding the potential performance and fundamental limitations of such technology, however, requires knowledge of the noise characteristics of the 3-D imaging system. The noise performance of a prototype flat-panel cone-beam CT (F...
متن کاملFast distance-driven projection and truncation management for iterative cone-beam CT reconstruction
The purpose of this study was to improve the speed of the Simultaneous Algebraic Reconstruction Technique (SART) for truncated cone-beam (CB) projections using a distance-driven forward projector. First, we optimized the innermost loop of the projector for a cone-beam scanner with a circular source trajectory and a flat-panel imager. We showed that the innermost loop of the distance-driven proj...
متن کاملThe influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors.
The influence of antiscatter x-ray grids on image quality in cone-beam computed tomography (CT) is evaluated through broad experimental investigation for various anatomical sites (head and body), scatter conditions (scatter-to-primary ratio (SPR) ranging from approximately 10% to 150%), patient dose, and spatial resolution in three-dimensional reconstructions. Studies involved linear grids in c...
متن کاملOptimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography).
A theoretical method is presented that allows identification of optimal x-ray imaging geometry, considering the effects of x-ray source distribution, imaging task, x-ray scatter, and imager detective quantum efficiency (DQE). Each of these factors is incorporated into the ICRU-recommended figure of merit for image quality, the detectability index, which is maximized to determine the optimal sys...
متن کاملLow‐dose 2.5 MV cone‐beam computed tomography with thick CsI flat‐panel imager
Most of the treatment units, both new and old models, are equipped with a megavoltage portal imager but its use for volumetric imaging is limited. This is mainly due to the poor image quality produced by the high-energy treatment beam (> 6MV). A linac at our center is equipped with a prototype 2.5 MV imaging beam. This study evaluates the feasibility of low-dose megavoltage cone-beam imaging wi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 27 6 شماره
صفحات -
تاریخ انتشار 2000