Abrasion of abutment screw coated with TiN
نویسندگان
چکیده
STATEMENT OF PROBLEM Screw loosening has been a common complication and still reported frequently. PURPOSE The purpose of this study was to evaluate abrasion of the implant fixture and TiN coated abutment screw after repeated delivery and removal with universal measuring microscope. MATERIAL AND METHODS Implant systems used for this study were Osstem and 3i. Seven pairs of implant fixtures, abutments and abutment screws for each system were selected and all the fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. After 20 times of repeated closing and opening test, the evaluation for the change of inner surface of implant and TiN-coated abutment screw, and weight loss were measured. Mann-Whitney test with SPSS statistical software for Window was applied to analyze the measurement of weight loss. RESULTS TiN-coated abutment screws of Osstem and 3i showed lesser loss of weight than non-coated those of Osstem and 3i (P < .05, Mann-Whitney test). CONCLUSION Conclusively, TiN coating of abutment screw showed better resistance to abrasion than titanium abutment screw. It was concluded that TiN coating of abutment screw would reduce the loss of preload with good abrasion resistance and low coefficient of friction, and help to maintain screw joint stability.
منابع مشابه
Effect of Tin Coating of Abutment Screw on Detorque Force
Purpose. The aim of this study is to evaluate the effect of TiN coating of abutment screw on the unscrewing torque. Material and methods. Titanium and Gold-Tite abutment screws were classified into two groups, Group A and C respectively, as control groups. Titanium abutment screws with TiN coatings were also classified into two groups, Group B and D, as experimental ones. Group A and B were tig...
متن کاملAn abutment screw loosening study of a Diamond Like Carbon-coated CP titanium implant.
The aim of this study was to quantify the extent of abutment screw loosening and thus understand the role of frictional and wear factors in abutment screw loosening by using a cyclic loading device to compare Diamond Like Carbon (DLC)-coated and non-coated implants. The properties of DLC films, including hardness, wear resistance, chemical stability, and biocompatibility, are similar to those o...
متن کاملComparison of the Effect of Two Different Abutment Diameters on Detorque Value Using Cyclic Loading and Thermocycling
Background and Aim: Screw loosening is a common problem with both screw-retained and cemented implant restorations. It is assumed that the abutment diameter affects detorque value and screw loosening. We aimed to determine the effect of two different abutment diameters on detorque value using cyclic loading and thermocycling. Materials and Methods: This in-vitro experimental study was conducte...
متن کاملEffect of Abutment Connection Type and Cyclic Loading on Removal Torque Value
Background and Aim: Maintaining the primary torque of the abutment screw is a common problem related to implant-supported restorations; a failure in this respect often leads to screw loosening. The abutment screw plays a critical role in the long-term stability of restorations. This study aimed to assess the effect of two abutment connection types with and without cyclic loading on removal torq...
متن کاملInfluence of diamondlike carbon-coated screws on the implant-abutment interface.
PURPOSE To evaluate the implant-abutment interface area and the abutment screw loosening value when diamondlike carbon (DLC)-coated or titanium screws were used before and after cyclic loading. MATERIALS AND METHODS Thirty-six implants were divided into four groups according to the type of connection (external hexagon [EH] or internal hexagon [IH]) and the type of abutment screw (with [EHD/IH...
متن کامل