Minimal adhesion surface area in tangentially loaded digital contacts.
نویسندگان
چکیده
The stick-to-slip transition of a fingertip in contact with a planar surface does not occur instantaneously. As the tangential load increases, portions of the skin adhere while others slip, giving rise to an evolution of the contact state, termed partial slip. We develop a quasi-static model that predicts that if the coefficient of kinetic friction is larger than the coefficient of static friction, then the stuck surface area diminishes as the tangential load increases until reaching a 'minimal adhesion surface area' where it vanishes abruptly. This phenomenon was observed in recently measured finger-slip image data (André et al., 2011) that were processed by an optic flow detection algorithm. We examined the results of 10 trials. Four of them exhibited the minimal adhesion surface area phenomenon, four of them did not, and two were inconclusive.
منابع مشابه
Effects of titania nanotubes with or without bovine serum albumin loaded on human gingival fibroblasts
Modifying the surface of the transmucosal area is a key research area because this process positively affects the three functions of implants: attachment to soft tissue, inhibiting bacterial biofilm adhesion, and the preservation of the crestal bone. To exploit the potential of titania nanotube arrays (TNTs) with or without using bovine serum albumin (BSA) to modify the surface of a dental impl...
متن کاملFabrication of novel tubular scaffold for tendon repair from chitosan in combination with zinc nanoparticles
Chitosan bears numerous properties, such as biocompatibility, biodegradability and non-toxicity making it suitable for use in different biomedical fields. Zinc (Zn) is required for fibroblasts proliferation and collagen synthesis as essential elements of wound healing. Its nanoparticles are well known for their capability to enhance wound healing by cell adhesion and migration improvement throu...
متن کاملHydrodynamic and Elastohydrodynamic Lubrication
Contents 1. Introduction 2. Stress-induced lubricant degradation 3. Basic equations governing the fluid elastohydrodynamic lubrication (EHL) of line and point contacts 3.1. Equations of fluid motion 3.2. Contact surface displacements in line and point lubricated contacts 4. Steady isothermal EHL problems for lightly loaded non-conformal line contacts 5. Steady isothermal EHL problems for heavil...
متن کاملImplants modified with polymeric nanofibers coating containing the antibiotic vancomycin
Objective(S): Implant-related infections are disastrous complications in the clinic. One recent strategy to reduce the rate of infection is using the bioactive coating with an antibiotic. The purpose of these bioactive surfaces is to prevent bacterial adhesion to the implant and, consequently, the development of biofilm. In this study, vancomycin-loaded polymeric coating on imp...
متن کاملDrug-loaded electrospun nanofibrous sheets as barriers against postsurgical adhesions in mice model
Objectives: Postsurgical adhesion is one of the common complications after surgery. Some anti-adhesion barriers are commercially available which are not customary used by physicians as much as expected because of ineffectiveness. Recently, nanofibers have been introduced as anti-adhesion barriers with t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanics
دوره 44 13 شماره
صفحات -
تاریخ انتشار 2011