High dispersion of ventricular repolarization after an implantable defibrillator shock predicts induction of ventricular fibrillation as well as unsuccessful defibrillation.

نویسندگان

  • J B Moubarak
  • P E Karasik
  • R D Fletcher
  • M R Franz
چکیده

OBJECTIVES To test the hypothesis that post-shock dispersion of repolarization (PSDR) is higher in T wave shocks that induce ventricular fibrillation (VF) than in those that do not, as well as in implantable cardioverter defibrillator (ICD) defibrillation shocks which fail to terminate VF when compared with those that are successful. BACKGROUND Ventricular fibrillation has been linked to the presence of dispersion of repolarization, which facilitates reentry. Most of the studies have been done in animals, and the mechanism underlying the generation and termination of VF in humans is speculative and remains to be determined. METHODS Monophasic action potentials (MAPs) were recorded simultaneously from the right ventricular outflow tract (RVOT) and the right ventricular apex (RVA) in 27 patients who underwent implantation and testing of an ICD. T wave shocks were used to induce VF while the termination was attempted using internal defibrillator shocks. The post-shock repolarization time (PSRT) was measured in both the RVA and RVOT MAPs, and the difference between the two recordings was defined as the PSDR. The averages of PSDR were compared between the successful and unsuccessful inductions and terminations of VF. RESULTS T wave shocks that induced VF generated a greater PSDR (93.4 +/- 85.1 ms) than the unsuccessful ones (45.1 +/- 55.9 ms, p < 0.001). On the other hand, shocks that failed to terminate VF were associated with a greater PSDR (59.9 +/- 41.2 ms) than shocks that terminated VF (21.1 +/- 20.1 ms), p < 0.001. CONCLUSIONS A high PSDR following a T wave shock is associated with induction of VF; while following a defibrillating shock, it is associated with its failure and the continuation of VF. Conversely, a low PSDR is associated with failure of a T wave shock to induce VF and successful termination of VF by a defibrillating shock.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Basic Mechanism of Defibrillation Failure

Delivery of a strong electric shock to the heart remains the only effective therapy against ventricular fibrillation. Despite significant improvements in implantable cardioverter defibrillator (ICD) therapy, the fundamental mechanisms of defibrillation remain poorly understood. We have recently demonstrated that a monophasic defibrillation shock produces a highly nonuniform epicardial polarizat...

متن کامل

Mechanisms of Defibrillation Failure

Since defibrillation by high-energy electric shocks is the only effective means for termination of ventricular fibrillation, defibrillation shocks are now widely used in clinical practice for prevention of sudden cardiac death. However, the high-energy shocks could result in myocardial dysfunction and damage (Runsio et al., 1997) and in psychological trauma (Maisel, 2006). Comprehensive underst...

متن کامل

Mechanism of cardiac defibrillation in open-chest dogs with unipolar DC-coupled simultaneous activation and shock potential recordings.

The automatic implantable cardioverter-defibrillator has been shown to dramatically improve survival. The future refinement of these devices requires a clear understanding of their mechanism of action. We performed the following study to test two hypotheses: 1) When defibrillation is successful, fibrillating activity must be annihilated in a critical mass of both ventricles; and 2) when defibri...

متن کامل

Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations).

BACKGROUND Implantable cardioverter-defibrillators and cardiac resynchronization therapy defibrillators have relied on multiple ventricular fibrillation (VF) induction/defibrillation tests at implantation to ensure that the device can reliably sense, detect, and convert VF. The ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduc...

متن کامل

Ensuring automatic detection of ventricular fibrillation.

T he sensitivity and specificity of ventricular fibrillation (VF) detection by automatic implantable cardioverter-defibrillators (ICDs) have received relatively little attention by clinical investigators compared with other aspects of defibrillator use. The paucity of reports on ventricular fibrillation detection is not related to its lack of importance but rather reflects how difficult it is t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 35 2  شماره 

صفحات  -

تاریخ انتشار 2000