A single supply biopotential amplifier.
نویسندگان
چکیده
A biopotential amplifier for single supply operation is presented. It uses a Driven Right Leg Circuit (DRL) to drive the patient's body to a DC common mode voltage, centering biopotential signals with respect to the amplifier's input voltage range. This scheme ensures proper range operation when a single power supply is used. The circuit described is especially suited for low consumption, battery-powered applications, requiring a single battery and avoiding switching voltage inverters to achieve dual supplies. The generic circuit is described and, as an example, a biopotential amplifier with a gain of 60 dB and a DC input range of +/-200 mV was implemented using low power operational amplifiers. A Common Mode Rejection Ratio (CMRR) of 126 dB at 50 Hz was achieved without trimming.
منابع مشابه
A 0.8 V CMOS OTA and Its Application in Realizing a Neural Recording Amplifier
This work presents a low-voltage, low power CMOS symmetrical operational transconductance amplifier (OTA) and its application for realization of a biopotential amplifier in neural recording application. The linear range of OTA is increased by employing multi-tanh differential configuration and source degeneration while the commonmode range is enhanced using DC-shifting scheme. The proposed symm...
متن کاملA Low Power Low Noise Two Stage CMOS Operational Amplifier for Biopotential Signal Acquisition System
Monitoring of the biopotential signals in present scenario attract much attention to the researcher due to increasing demand for better quality of life and to enhance interaction between humans and machines. Biopotential signals are relatively weak amplitude and low frequency in nature. Therefore it is required to design a front circuitry that defines quality of signal for processing to the nex...
متن کاملFully Integrated Biopotential Acquisition Analog Front-End IC
A biopotential acquisition analog front-end (AFE) integrated circuit (IC) is presented. The biopotential AFE includes a capacitively coupled chopper instrumentation amplifier (CCIA) to achieve low input referred noise (IRN) and to block unwanted DC potential signals. A DC servo loop (DSL) is designed to minimize the offset voltage in the chopper amplifier and low frequency respiration artifacts...
متن کاملImproving Linearity of CMOS Variable-gain Amplifier Using Third-order Intermodulation Cancellation Mechanism and Intermodulation Distortion Sinking Techniques
This paper presents an improved linearity variable-gain amplifier (VGA) in 0.18-µm CMOS technology. The linearity improvement is resulted from employing a new combinational technique, which utilizes third-order-intermodulation (IM3) cancellation mechanism using second-order-intermodulation (IM2) injection, and intermodulation distortion (IMD) sinking techniques. The proposed VGA gain cell co...
متن کاملRelative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier 601 Relative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier
In this paper, we propose a simple and relative electrode contact monitoring method. By exploiting the power line interference, which is regarded as one of the worst noise sources for bio-potential measurement, the relative difference in electrode impedance can be measured without a current or voltage source. Substantial benefits, including no extra circuit components, no degradation of the bod...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical engineering & physics
دوره 23 3 شماره
صفحات -
تاریخ انتشار 2001