Tidal volume dependency of gas exchange in bronchoconstricted pig lungs.
نویسندگان
چکیده
Independent of airway pressure, pulmonary resistance is known to fall with increasing tidal volumes, traditionally thought to result from radial traction on the airways. R. C. Anafi and T. A. Wilson (J Appl Physiol 91: 1185-1192, 2001) recently presented a model of a single terminal airway that explains the tidal volume-associated fall in resistance with an additional mechanism pertinent to narrow airways: a stable, nearly closed airway that is challenged with an increase in tidal volume "pops open" to become a stable, well-opened airway, and thus resistance drops suddenly. To test this model in vivo, the effects of high (24 ml/kg) and low (9 ml/kg) tidal volume in bronchoconstricted lungs were assessed using 1) the multiple inert gas elimination technique (MIGET) and 2) a 15-breath multiple breath inert gas washout (MBW) technique in anesthetized pigs. With high tidal volume, ventilation/perfusion (Va/Q) mismatch was reduced (log SD Q from 1.30 +/- 0.11 to 1.09 +/- 0.12, P < 0.05), and blood flow to lung units with Va/Q ratios < 0.1 was significantly reduced (37 +/- 4% of cardiac output to 7 +/- 4%, P < 0.05). Dynamic compliance was twice as high during high-tidal-volume ventilation (P = 0.002). MBW analysis revealed that, while heterogeneity of ventilation during bronchoconstriction was not significantly different between either low or high tidal volume (log SD Vmbw = 1.39 +/- 0.09 and 1.34 +/- 0.02, respectively), preinspiratory lung volume (PILV) decreased by 42% with low-tidal-volume ventilation (P < 0.05), whereas it did not change with high-tidal-volume ventilation. The higher PILV during high tidal volume is also consistent with Anafi and Wilson's model. In summary, the outcomes from MIGET, and to some extent the MBW, in our anesthetized and mechanically ventilated pigs are consistent with a bistable terminal airway model as proposed by Anafi and Wilson. However, our data do not allow exclusion of other mechanisms that may lead to improved ventilatory distribution when tidal volume is increased.
منابع مشابه
Large tidal volume ventilation improves pulmonary gas exchange during lower abdominal surgery in Trendelenburg's position.
Impaired pulmonary gas exchange is a common complication of general anaesthesia. Periodic hyperinflation of the lungs and large tidal volume ventilation were the first preventive measures to be widely embraced, but their effectiveness in clinical practice has never been clearly established by controlled clinical studies. To assess their effects in high-risk patients we studied 24 adults having ...
متن کاملAn appropriate inspiratory flow pattern can enhance CO2 exchange, facilitating protective ventilation of healthy lungs.
BACKGROUND In acute lung injury, CO2 exchange is enhanced by prolonging the volume-weighted mean time for fresh gas to mix with resident alveolar gas, denoted mean distribution time (MDT), and by increasing the flow rate immediately before inspiratory flow interruption, end-inspiratory flow (EIF). The objective was to study these effects in human subjects without lung disease and to analyse the...
متن کاملCurrent methodological and technical limitations of time and volumetric capnography in newborns
Although capnography is a standard tool in mechanically ventilated adult and pediatric patients, it has physiological and technical limitations in neonates. Gas exchange differs between small and adult lungs due to the greater impact of small airways on gas exchange, the higher impact of the apparatus dead space on measurements due to lower tidal volume and the occurrence of air leaks in intuba...
متن کاملHydrogen inhalation ameliorates ventilator-induced lung injury
INTRODUCTION Mechanical ventilation (MV) can provoke oxidative stress and an inflammatory response, and subsequently cause ventilator-induced lung injury (VILI), a major cause of mortality and morbidity of patients in the intensive care unit. Inhaled hydrogen can act as an antioxidant and may be useful as a novel therapeutic gas. We hypothesized that, owing to its antioxidant and anti-inflammat...
متن کاملIs smaller high enough? Another piece in the puzzle of stress, strain, size, and systems
Extracorporeal lung-supporting procedures open the possibility of staying within widely accepted margins of 'protective' mechanical ventilation (tidal volume of less than 6 mL per kg of predicted ideal body weight and plateau pressure of less than 30 cm H2O) in most any case of respiratory failure or even of further reducing ventilator settings while still providing adequate gas exchange. There...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 103 1 شماره
صفحات -
تاریخ انتشار 2007