Monitoring of patient-ventilator interaction at the bedside.
نویسنده
چکیده
Monitoring of patient-ventilator interactions at the bedside involves evaluation of patient breathing pattern on ventilator settings. One goal of mechanical ventilation is to have ventilator-assisted breathing coincide with patient breathing. The objectives of this goal are to have patient breath initiation result in ventilator triggering without undue patient effort, to match assisted-breath delivery with patient inspiratory effort, and to have assisted breathing cease when the patient terminates inspiration, thus avoiding ventilator-assisted inspiration during patient exhalation. Asynchrony can occur throughout the respiratory cycle, and this paper describes common asynchronies. The types of asynchronies discussed are trigger asynchrony (ie, breath initiation that may manifest as ineffective triggering, double-triggering, or auto-triggering); flow asynchrony (ie, breath-delivery asynchrony, which may manifest as assisted-breath delivery being faster or slower than what patient desires); and cycling asynchronies (ie, termination of assisted inspiration does not coincide with patient breath termination, which may manifest as delayed cycling or premature cycling). Various waveforms are displayed and graphically demonstrate asynchronies; basic principles of waveform interpretation are discussed.
منابع مشابه
Observational study of head of bed elevation adherence using a continuous monitoring system in a medical intensive care unit.
BACKGROUND Head of bed elevation ≥ 30° reduces ventilator-associated pneumonia in mechanically ventilated patients, but adherence is variable and difficult to monitor continuously. Unlike many clinical variables, head of bed elevation is not electronically displayed or monitored with audible alarms. HYPOTHESIS Continuous monitoring of head of bed elevation with audible alerts and visual cues...
متن کاملAutomated detection of patient-ventilator asynchrony: new tool or new toy?
Although severe patient-ventilator asynchrony is frequent during invasive and non-invasive mechanical ventilation, diagnosing such asynchronies usually requires the presence at the bedside of an experienced clinician to assess the tracings displayed on the ventilator screen, thus explaining why evaluating patient-ventilator interaction remains a challenge in daily clinical practice. In the prev...
متن کاملMeasurement of air trapping, intrinsic positive end-expiratory pressure, and dynamic hyperinflation in mechanically ventilated patients.
Severe airflow obstruction is a common cause of acute respiratory failure. Dynamic hyperinflation affects tidal ventilation, increases airways resistance, and causes intrinsic positive end-expiratory pressure (auto-PEEP). Most patients with asthma and chronic obstructive pulmonary disease have dynamic hyperinflation and auto-PEEP during mechanical ventilation, which can cause hemodynamic compro...
متن کاملAn automated and standardized neural index to quantify patient-ventilator interaction
INTRODUCTION The aim of this study was to validate an automated, objective and standardized algorithm for quantifying and displaying patient-ventilator interaction. METHODS Using a new method to detect patient-ventilator synchrony, the present study re-analyzed previously acquired and published data from 24 mechanically ventilated adult patients (Colombo et al., Crit Care Med. 2011 Nov;39(11)...
متن کاملBedside detection of patient-ventilation asynchrony
Patient-ventilator asynchrony is common but under-recognized and under-reported. The frequency of PAV is reported around 23%, but up to 93% of patients have at least one episode of PVA. While sporadic asynchronies may have uncertain clinical impact, when they amount to more than 10% of the total breaths, PVA can increase the need for sedation and reduce sleep quality. In addition, they can impa...