Screw loosening with interchangeable abutments in internally connected implants after cyclic loading.

نویسندگان

  • Seong Kyun Kim
  • Jai Young Koak
  • Seong Joo Heo
  • Thomas D Taylor
  • Sook Ryoo
  • Su Young Lee
چکیده

PURPOSE The purpose of this study was to observe and compare any loosening of screws attaching several interchangeable abutments to internally connected implants after cyclic loading. MATERIALS AND METHODS Four different abutment groups mated with Straumann single-stage transmucosal implants (n = 7 each group) were assessed: Straumann solid abutment, Restore COC abutment, Neoplant solid abutment, and AVANA solid abutment. Each implant was fixed rigidly in a special holding jig. Abutments were tightened to 35 Ncm with a torque controller. A cyclic load of 150 N at a 30-degree angle to the long axis was applied to the implants for 1 million cycles. Prior to loading, Periotest values (PTVs) were measured. After cyclic loading, PTVs were measured and removal torque values (RTVs) of abutments were measured with a digital torque gauge. RESULTS No mechanical failures were noted for the Straumann solid abutment or the Restore COC abutment. Six Neoplant abutment screws fractured (86%), and four implants fractured (57%) in the group restored with AVANA solid abutments. The RTVs of the Straumann solid abutment were significantly higher than those of the other abutments. The final mean PTV of the Straumann solid abutment was significantly lower than the final mean PTVs of the other abutments. The final mean PTV (4.76 ± 5.58) was significantly higher than the initial mean PTV (-4.29 ± 0.47). CONCLUSIONS Although different abutments are interchangeable with each other, they possess different chemical compositions and physical characteristics. The use of an abutment and implant manufactured by the same company is recommended to prevent the loosening of the abutment screw.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Effect of Two Different Abutment Diameters on Detorque Value Using Cyclic Loading and Thermocycling

Background and Aim: Screw loosening is a common problem with both screw-retained and cemented implant restorations. It is assumed that the abutment diameter affects detorque value and screw loosening. We aimed to determine the effect of two different abutment diameters on detorque value using cyclic loading and thermocycling. Materials and Methods: This in-vitro experimental study was conducte...

متن کامل

Effect of Abutment Connection Type and Cyclic Loading on Removal Torque Value

Background and Aim: Maintaining the primary torque of the abutment screw is a common problem related to implant-supported restorations; a failure in this respect often leads to screw loosening. The abutment screw plays a critical role in the long-term stability of restorations. This study aimed to assess the effect of two abutment connection types with and without cyclic loading on removal torq...

متن کامل

بررسی میزان کاهش تورک در اباتمنت‌های کست شونده با آلیاژ کروم کبالت پس از اعمال بارگذاری دوره‌ای

Background and Aims: For the clinical success of implant-retained prostheses, fitness of matching components and stability of the applied torque to the implant-abutment assembly under dynamic occlusal loading is essential. The aim of this study was to evaluate the torque loss in Co-Cr castable abutments after cyclic loading. Materials and Methods: 10 castable abutments were cast in Co-Cr alloy...

متن کامل

Zirconium implant abutments: fracture strength and influence of cyclic loading on retaining-screw loosening.

OBJECTIVE The purpose of this study was to determine the fracture strength of zirconium implant abutments and the torque required to unfasten the retaining screw before and after applying cyclic loading to the implant-abutment assembly. The dynamic behavior and stress distribution pattern of zirconium abutments were also evaluated. METHODS AND MATERIALS Static and cyclic loading of 7 XiVE imp...

متن کامل

Influence of the implant abutment types and the dynamic loading on initial screw loosening

PURPOSE This study examined the effects of the abutment types and dynamic loading on the stability of implant prostheses with three types of implant abutments prepared using different fabrication methods by measuring removal torque both before and after dynamic loading. MATERIALS AND METHODS Three groups of abutments were produced using different types of fabrication methods; stock abutment, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 27 1  شماره 

صفحات  -

تاریخ انتشار 2012