Undiagnosed cardiomyopathy in a neonate: significance of low oxygen saturation during anaesthesia.
نویسندگان
چکیده
A case study is described of a 7-day-old full term baby with bilateral congenital cataracts who underwent surgical removal of both cataracts 2 days apart. Problems with oxygen saturation during and after the first anaesthetic prompted further investigation that revealed a non-obstructive hypertrophic cardiomyopathy. The significance and possible causes of low oxygen saturation in a previously healthy neonate during anaesthesia are discussed. The likely diagnosis of Sengers syndrome, and the evaluation of asymptomatic babies with cardiac pathology are discussed.
منابع مشابه
مقایسه اثر تغذیه با پستان مادر و تغذیه با لوله بر میزان اشباع اکسیژن شریانی در نوزادان با وزن تولد کمتر از 1500 گرم
Background & Aim: Preterm infants born at less than 34 weeks postconceptional age are not as neurologically mature as their term counterparts and thus have difficulty coordinating sucking, swallowing and breathing. As a result, they are traditionally gavage fed until they are able to oral feed successfully. The aim of study was to evaluate comparative effect of orogastric and breast feeding...
متن کاملPeripartum cardiomyopathy undergoing caesarean section under epidural anaesthesia.
PURPOSE To report a case of peripartum dilated cardiomyopathy presenting for emergency caesarean section, this was successfully managed with Epidural Anaesthesia. CLINICAL FEATURES A parturient suffering from idiopathic peripartum cardiomyopathy (E.F. 18%) was brought for an emergency caesarean section. Epidural anaesthesia was performed and 2% Lignocaine with adrenaline total 13 ml was injec...
متن کاملHuman Oxygenation by Air during Anaesthesia: the Relation of Ventilatory Volume and Arterial Oxygen Saturation.
Ventilation and arterial oxygen saturation have been measured in 18 patients during anaesthesia with ether or halothane carried in air. All patients were ventilated artificially with a Jefferson ventilator at a frequency of 16 breaths per minute and variable tidal volume. Ventilation has been expressed as a percentage of Radford's standard, Nunn's standard and the patient's pre-operative restin...
متن کاملمقایسه وضعیتهای دمر و طاقباز بر اشباع اکسیژن شریانی در نوزادان بستری در بخش مراقبتهای ویژه نوزادان بعد از جداسازی ازدستگاه تهویه مکانیکی در بیمارستان افضلیپور کرمان در سال 1391
Background and Objective: The results of previous studies show the neonate position is effective in improving oxygenation . Therefore, this study aimed to compare the prone and supine positions on oxygen saturation in preterm infants who were weaned from mechanical ventilation. Materials and Methods: This clinical trial carried out on 40 preterm infants who were weaned from mechan...
متن کاملSedation during spinal anaesthesia: a case for the routine administration of oxygen.
We have studied the effect of sedation with midazolam on arterial oxygen saturation during spinal anaesthesia in two groups of patients: one group received supplementary oxygen, the other group breathed room air. A significant reduction in oxygen saturation was observed in patients not receiving supplementary oxygen; six of 15 patients in this group developed hypoxaemia or severe hypoxaemia whi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 86 3 شماره
صفحات -
تاریخ انتشار 2001