Ceramic Surface Engineered Metal-on-Metal Hips system for Total Hip Arthroplasty and Resurfacing Hip Arthroplasty
نویسنده
چکیده
components for the reconstruction of the acetabulum and metal femoral head components for conventional THA and RHA. The ACCIS®metal components are made of a chrome-cobalt-molybdenum alloy, but are different from other metal-on-metal prostheses. The surfaces of the metal components are engineered with the ceramic Titanium-Niobium-Nitride (TiNbN) in order to minimize metal particulate wear, to prevent corrosion and to prevent metal ion release. Ceramic Surface Engineered Metal-on-Metal Hips system for Total Hip Arthroplasty and Resurfacing Hip Arthroplasty
منابع مشابه
Cementless Total Hip Arthroplasty Involving Trochanteric Osteotomy without Subtrochanteric Shortening for High Hip Dislocation
BACKGROUND Total hip arthroplasty with subtrochanteric shortening osteotomy is widely performed for high hip dislocation. However, suboptimal leg length discrepancy correction and nonunion of the osteotomy site remain concerns. Although total hip arthroplasty using trochanteric osteotomy without subtrochanteric osteotomy was introduced, cemented implants have been more commonly used than contem...
متن کاملA prospective randomized clinical trial comparing metal-on-metal total hip arthroplasty and metal-on-metal total hip resurfacing in patients less than 65 years old.
The purpose of this prospective randomised study is to compare the early clinical results of the metal-on-metal hip resurfacing to metal-on-metal THA. Two hundred and ten hips were randomised between August 2003 and January 2006 (191 subjects). One hundred and two hips were implanted with an uncemented titanium tapered stem, and an uncemented titanium acetabular component and 28 mm metal-on-met...
متن کاملFatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature
Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...
متن کاملRevision of Failed Hip Resurfacing and Large Metal-on-Metal Total Hip Arthroplasty Using Dual-Mobility Components.
Revision of metal-on-metal (MoM) total hip arthroplasty (THA) or hip resurfacing is associated with high complication rates. The authors propose dual-mobility components as a surgical option and present short- to mid-term results of MoM hips revised with dual-mobility components. Eighteen consecutive hips that underwent revision of MoM THA or hip resurfacing using dual-mobility components were ...
متن کاملFemoral neck fractures complicating metal-on-metal resurfaced hips: a report of 2 cases.
Metal-on-metal hip resurfacing arthroplasty is increasingly popular for younger patients with advanced hip disease. Intra-operative or immediate postoperative femoral neck fracture after metal-on-metal hip resurfacing is a well-described technical complication, ranging from 0% to 1.5%. We report 2 cases of late femoral neck fracture occurring 8 and 15 months following the index operation, with ...
متن کامل