A Simple Pattern Recognition Approach for Monitoring Incipient Stator Faults in Salient-pole Synchronous Generators

نویسندگان

  • J. A. Dente
  • P. J. C. Branco
چکیده

This paper studies the effect of incipient stator faults in salient-pole synchronous generators and its detection using a simple pattern recognition methodology. A theoretical linear model for the synchronous generator is first developed to provide the relationships between stator and rotor harmonic currents and possible incipient faults on stator electric circuits. All theoretical findings were verified by experimental results. The stator currents and its αβ and dq representations have been used to detect incipient faults on salient-pole synchronous generators using a similar pattern recognition technique which have been proposed for induction machines. From our test results, it became clear that the proposed methodology is capable of correctly monitoring incipient stator faults in salient-pole synchronous generators.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Magnetic Flux Linkage Distribution in Salient-Pole Synchronous Generator with Different Kinds of Inter-Turn Winding Faults

A reliable and accurate diagnosis of inter-turn short circuit faults is a challenging problem in the area of fault diagnosis of electrical machines. The purpose of this challenge is to be more efficient in fault detection and to provide a reliable method with low-cost sensors and simple numerical algorithms which not only detect the occurrence of the fault, but also locate its position in the w...

متن کامل

Internal Fault Detection, Location, and Classification in Stator Winding of the Synchronous Generators Based on the Terminal Voltage Waveform

In this paper, a novel method is presented for detection and classification of the faultyphase/region in the stator winding of synchronous generators on the basis of the resulting harmoniccomponents that appear in the terminal voltage waveforms. Analytical results obtained through DecisionTree (DT) show that the internal faults are not only detectable but also they can be classified andthe rela...

متن کامل

Inter-turn Fault Analysis of Synchronous Generator using Finite Element Method (FEM)

A turn fault in the stator winding of a generator causes a large circulating current to flow in the shorted turns. If left undetected, turn faults can propagate, leading to phaseground or phase-phase faults. Incipient detection of turn’s faults is essential to avoid hazardous operating conditions and reduce down time. At present the synchronous generators are protected against almost all kind o...

متن کامل

Pattern Classification based Intelligent Numerical Protection of Salient - pole Synchronous Generator using Neural Networks

This paper presents the application of neural networks for the non-differential protection of salient-pole synchronous generator against internal faults in any winding of the stator. The direct phase quantities and modified winding function approach has been used to simulate different types of internal and external faults using electrical parameters of generators installed by utilities. The cas...

متن کامل

A Simple Analytic Method to Model and Detect Non-Uniform Air-Gaps in Synchronous Generators

The air-gap of electrical machines may become non-uniform due to low accuracy of the manufacturing machinery, in assembling processes, or by aging. Detection and monitoring of this phenomenon is very important and of interest. There are several methods to model non-uniform air-gaps and to detect them by monitoring systems. One of the most widely used methods is by the analysis of the line curre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012