Preanalytical Nonconformity Management Regarding Primary Tube Mixing in Brazil
نویسندگان
چکیده
BACKGROUND The multifaceted clinical laboratory process is divided in three essential phases: the preanalytical, analytical and postanalytical phase. Problems emerging from the preanalytical phase are responsible for more than 60% of laboratory errors. This report is aimed at highlighting and discussing nonconformity (e.g., nonstandardized procedures) in primary blood tube mixing immediately after blood collection by venipuncture with evacuated tube systems. METHODS From January 2015 to December 2015, fifty different laboratory quality managers from Brazil were contacted to request their internal audit reports on nonconformity regarding primary blood tube mixing immediately after blood collection by venipuncture performed using evacuated tube systems. RESULTS AND CONCLUSIONS A minority of internal audits (i.e., 4%) concluded that evacuated blood tubes were not accurately mixed after collection, whereas more than half of them reported that evacuated blood tubes were vigorously mixed immediately after collection, thus magnifying the risk of producing spurious hemolysis. Despite the vast ma jority of centers declaring that evacuated blood tubes were mixed gently and carefully, the overall number of inversions was found to be different from that recommended by the manufacturer. Since the turbulence generated by the standard vacuum pressure inside the primary evacuated tubes seems to be sufficient for providing solubilization, mixing and stabilization between additives and blood during venipuncture, avoidance of primary tube mixing probably does not introduce a major bias in tests results and may not be considered a nonconformity during audits for accreditation.
منابع مشابه
Sources of preanalytical error in primary health care -Implications for patient safety
1 ORIGINAL ARTICLES 2 ABBREVIATIONS 3 DEFINITIONS 4 INTRODUCTION 5 Patient safety 5 Systems perspective 6 Primary health care 7 Laboratory testing 7 Venous blood sample collection 8 Context for blood sample collection 8 The total testing process 9 The preanalytical phase 11 Patient preparation 11 Patient identification 12 Test request management 12 Test tube labelling 13 Sample collection and h...
متن کاملTen years of preanalytical monitoring and control: Synthetic Balanced Score Card Indicator
INTRODUCTION Preanalytical control and monitoring continue to be an important issue for clinical laboratory professionals. The aim of the study was to evaluate a monitoring system of preanalytical errors regarding not suitable samples for analysis, based on different indicators; to compare such indicators in different phlebotomy centres; and finally to evaluate a single synthetic preanalytical ...
متن کاملEstimation of Preanalytical Uncertainty in Clinical Chemistry
Preanalytical uncertainty is attributable to variations in blood sample collection and sample handling before analysis. The aim of this study was to establish a modelling framework for estimating preanalytical uncertainty. There is a need for standardization on which uncertainty sources that should be included, and how the preanalytical uncertainty should be estimated. In Paper I, an uncertaint...
متن کاملA Consensus in Korea Regarding a Protocol to Reduce Preanalytical Sources of Variability in the Measurement of the Cerebrospinal Fluid Biomarkers of Alzheimer's Disease
Cerebrospinal fluid (CSF) can provide vital informative about pathological processes occurring in the brain. In particular, the CSF concentrations of Aβ42, tTau, and pTau181 are useful for the early diagnosis of Alzheimer's disease (AD). However, many studies have demonstrated that confounding factors related to the preanalytical processing of CSF can seriously influence measurements of these A...
متن کاملPrimary blood tubes mixing: time for updated recommendations.
Due to spasmodic efforts made by international organizations (1, 2) , national and international working groups on quality in laboratory medicine (3, 4) as well as from the activities and publications of several independent research teams (5 – 7) , the quality throughout the total testing process has dramatically increased over the past decades, especially in the manually intensive activities o...
متن کامل