The contribution of phonon scattering to high-resolution images measured by off-axis electron holography.

نویسندگان

  • C B Boothroyd
  • R E Dunin-Borkowski
چکیده

The contribution of electrons that have been phonon scattered to the lattice fringe amplitude and the background intensity of a high-resolution electron microscope (HREM) image is addressed experimentally through the analysis of a defocus series of energy-filtered off-axis electron holograms. It is shown that at a typical specimen thickness used for HREM imaging approximately 15% of the electrons that contribute to an energy-filtered image have been phonon scattered. At this specimen thickness, the phonon-scattered electrons contribute a lattice image of opposite contrast to the elastic lattice image. The overall lattice fringe contrast is then reduced to 70% of the value that it would have in the absence of phonon scattering. At higher specimen thickness, the behaviour is defocus-dependent, with the phonon image having lattice fringe contrast of either the same or the opposite sense to the elastic image as the defocus is varied.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermal diffuse scattering in sub-angstrom quantitative electron microscopy-phenomenon, effects and approaches.

This paper reviews the recent progress in the following areas. (1) In quantitative high-resolution transmission electron microscopy, the theoretically calculated images usually give better contrast than the experimentally observed ones although all of the factors have been accounted for. This discrepancy is suggested due to thermal diffusely scattered (TDS) electrons, which were not included in...

متن کامل

The phonon contribution to high-resolution electron microscope images.

The amount of phonon scattering as a function of specimen thickness is determined for a clean silicon sample, free from amorphous surface layers, by measuring the diffuse scattering in energy-filtered convergent-beam diffraction patterns. It is found that for a 25 nm thick sample, only 7.5% of the intensity scattered to less than 18 nm(-1) is phonon scattered. This means that in a typical high-...

متن کامل

Off-axis electron holography of magnetic nanowires and chains, rings, and planar arrays of magnetic nanoparticles.

A selection of recent results illustrating the application of off-axis electron holography to the study of magnetic microstructure in closely-spaced nanoparticles and nanowires is reviewed. Examples are taken from the characterization of FeNi nanoparticle chains, Co nanoparticle rings, two-dimensional arrays of naturally occurring magnetite crystals in minerals, and single crystalline Co nanowi...

متن کامل

Towards quantitative electrostatic potential mapping of working semiconductor devices using off-axis electron holography.

Pronounced improvements in the understanding of semiconductor device performance are expected if electrostatic potential distributions can be measured quantitatively and reliably under working conditions with sufficient sensitivity and spatial resolution. Here, we employ off-axis electron holography to characterize an electrically-biased Si p-n junction by measuring its electrostatic potential,...

متن کامل

Holography and transmission electron microscopy

The basic principles and methods of off-axis electron holography are presented and illustrated by means of three examples related to its application in high resolution electron microscopy and the investigation of electric and magnetic fields in thin specimens.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultramicroscopy

دوره 98 2-4  شماره 

صفحات  -

تاریخ انتشار 2004