Beam-based Offset Calibration of the Pls Bpm
نویسندگان
چکیده
There are 108 beam position monitors in the PLS for the orbit measurement and closed orbit correction. As the BPM pickup electrodes are assembled directly on the 10m-long vacuum chamber, calibration of the electrical center of BPMs have been done with the external rf transmission-reflection method. Since the closed orbit distortion is still larger than 500 mm rms, we are developing the beam-based calibration method for the BPMs in PLS to improve the accuracy of the absolute position reading. In this report we present the method of beam-based calibration of BPMs and its experimental results.
منابع مشابه
Beam Position Monitors Characterization for Alba
Beam position monitors (BPM) characterization has been widely studied at ALBA Synchrotron Light Source. Special care has been taken on the analysis of their electrical offset in order to achieve submicron beam stabilities. This paper shows the results of the BPM offset study for Booster and Storage Ring. The electrical effect of the different vacuum vessels housing the BPMs is also reported.
متن کاملBeam Position Monitor Offset Determination at Lep
For the performance of an electron positron storage ring it is important that the beam orbit passes well centred through the quadrupole magnets. Beam position monitors (BPM) aligned relative to the magnets can still have a residual mechanical or electronical offset with respect to the magnetic axis. A beam-based method is used at LEP to measure these offsets. During the machine operation for ph...
متن کاملThe Calibration of BEPC Beam Position Monitors
The basic requirement for the BEPC beam position monitor is the measurement of the beam orbit with 0.1 mm precision near the collision point. To improve the measurement accuracy, the response of the beam position monitor pickups was mapped in the laboratory before they were installed in the BEPC ring. The microcomputer-controlled test set consists of high frequency coaxial switches to select ea...
متن کاملThe DELTA Beam-Based BPM Calibration System
A third-generation synchrotron light source like DELTA (1) requires a measuring system to determine the beam position with high resolution and great accuracy with respect to the center of the quadrupole magnets. This paper presents the beam-based BPM calibration system developed for DELTA, providing a calibration accuracy of about 150 μm. We describe the basic idea of the measurements, the inst...
متن کاملDevelopment of a Prototype Capacitive Bpm for the University of Maryland Electron Ring
Work has been performed at the University of Maryland by the electron beam physics group to design and develop a prototype capacitive Beam-Position-Monitor (BPM) for an electron ring project. Extensive theoretical work and PSPICE simulation of the equivalent circuit of the BPM have been conducted to fully understand the behaviour of the capacitive BPM. This BPM has 4 pieces of electrostatic pic...