Validation of IAEA software package for the analysis of scintigraphic renal dynamic studies: parameters of renal transit in children with renal pelvic dilatation.

نویسندگان

  • Slobodanka Lj Beatovic
  • Dragana P Sobic-Saranovic
  • Emilija D Jaksic
  • Milica M Jankovic
  • Jelena Marinkovic
  • Vladimir B Obradovic
چکیده

PURPOSE The objectives of the study were to use the International Atomic Energy Agency (IAEA) software package for the analysis of scintigraphic renal dynamic studies to obtain values of curve parameters and excretory parameters in children with hydronephrosis and to validate the reliability of these numerical outputs by comparing with values established by consensus reports. PATIENTS AND METHODS Fifty children with hydronephrosis (median age, 16 months; 30 boys, 20 girls; 99 kidneys) underwent Tc-MAG3 diuresis renography. Studies were analyzed by 2 observers, and according to the assessment of images, renograms, and differential function, kidneys were classified as normal (42, kidneys contralateral to hydronephrotic kidney), hypotonic unobstructed (49), and obstructed (8). The IAEA software was applied to each renogram. The parameters analyzed were as follows: normalized residual activity at 20 minutes (NORA 20) and on postmicturition (PM) acquisition, output efficiency at 20 minute (OE 20), PM to maximum renal count ratio (PM/max), and mean transit time (MTT). RESULTS Mean values for normal, hypotonic unobstructed, and obstructed kidneys were as follows: NORA 20: 0.25, 0.57, and 2.16; OE 20 (%): 94.5, 87, and 57; normalized residual activity on PM acquisition: 0.02, 0.03, and 0.27; PM/max: 0.01, 0.02, and 0.13; and MTT (minutes): 1.9, 3.5, and 8.9, respectively. Difference between obstruction/dilatation and normal/dilatation was significant (P < 0.0001), as well as the correlation between NORA 20/OE 20 (R = -0.982). Cutoff values to predict obstruction were as follows: NORA 20, 1.6; OE 20, 73%; NORA PM, 0.11; PM/max, 0.06; and MTT, 8.23 minutes. CONCLUSIONS The IAEA software package gives reliable values of numerical parameters of renal excretion. The use of the software improves diagnostic accuracy of diuresis renography in children.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of deconvolution technique for diagnosis of hydronephrosis in infants (under 6 months) [persian]

Introduction: Hydronephrosis is one of the major causes of referring infants for nuclear medicine investigation. Renal dynamic study is the most reliable investigation for such children. However direct evaluation of renogram leads to generation of parameters that have no physiological interpretation. The configuration of renogram is very much dependent upon the rate at which radiopharmace...

متن کامل

بررسی علل هیدرونفروز قبل از تولد و رابطه آن با شدت اتساع لگنچه در نوزادان و شیر خواران

Introduction & Objective: Prenatal hydronephrosis is increasingly reported because of more extensive application of prenatal sonography in the recent decades. Determination of causes of prenatal hydronephrosis could help in better recognition of natural course of disease and designing proper treatment protocol. On the other hand, severity of renal pelvic dilatation in the first sonograph...

متن کامل

Calculation of 99mTc-DTPA transit times in normal kidney [Persian]

Introduction: Renal dynamic study is a well-established and popular test in routine practice of nuclear medicine. The test is non-invasive, rapid and unique in evaluation of the kidney function. In despite of its clinical values, the parameters derived from renogram are physiologically meaningless. That is due to the fact that renogram is not the true kidney function. From mathematical po...

متن کامل

Quantitative and Qualitative Scintigraphic Measurement of Renal Function in Persian Cat Using 99mTechnetium Ethylenedicysteine and 99mTechnetium Diethylenetriaminepentaacetic

Objective- To consider the use of renal scintigraphic evaluation of kidney function in Persian cat and make a comparison between 99mTechnetium ethylenedicysteine and 99mTechnetium diethylenetriaminepentaacetic in renal scintigraphy. Design- Descriptive study Animals- 6 male healthy adult Persian cats - no clinical sign of renal disorders and prior to presentation. Proce...

متن کامل

Effect of Olive Leaf Extract inInhibition of Renal Ischemia- Reperfusion Injuries in Rat

Introduction: Renal Ischemia Reperfusion is considered to be one of the causes of acute renal failure (AKI). In addition, renal ischemia is an important incident usually occurs due to renal transplantion, repair of suprarenal aneurysm, hemorrhagic shock. A recent study reported that reactive oxygen species (ROS) are important mediators of AKI. It seems essential to use antioxidant to decrease t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical nuclear medicine

دوره 39 7  شماره 

صفحات  -

تاریخ انتشار 2014