Comparison of Radiation Exposure during Fluoroscopy-Guided Transforaminal Epidural Steroid Injections at Different Vertebral Levels

نویسندگان

  • Yun Mi Hwang
  • Min Hee Lee
  • Seon-Jeong Kim
  • Sheen-Woo Lee
  • Hye Won Chung
  • Sang Hoon Lee
  • Myung Jin Shin
چکیده

OBJECTIVE To estimate and compare radiation exposure during transforaminal fluoroscopy-guided epidural steroid injection (TFESI) at different vertebral levels. MATERIALS AND METHODS Fluoroscopy-guided TFESI was performed in 181 patients. The patients were categorized into three groups according to the injected lumbosacral nerve level of L2-4, L5, or S1. Fluoroscopy time (FT) and dose area product (DAP) were recorded for all patients; correlations between FT and DAP were determined at each level, and both FT and DAP were compared between the different vertebral levels. RESULTS The numbers of patients who received ESI at L2-4, L5, and S1 were 29, 123, and 29. Mean FT was 44 seconds at L2-4, 33.5 seconds at L5, and 37.7 seconds at S1. Mean DAP was 138.6 µGy·m(2) at L2-4, 100.6 µGy·m(2) at L5, and 72.1 µGy·m(2) at S1. FT and DAP were positively correlated in each group (p values < 0.001). FT was significantly shorter at L5 than that at L2-4 (p = 0.004) but was not significantly different between S1 and L2-4 or L5 (p values = 0.286 and 0.532, respectively). DAP was significantly smaller at L5 and S1 than that at L2-4, but L5 and S1 were not significantly different. After correcting for FT, DAP was significantly smaller at S1 than that at either L2-4 or L5 (p values = 0.001 and 0.010). CONCLUSION The radiation dose was small during a single procedure of ESI and showed differences between different lumbosacral spine levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of incidence of intravascular injections during transforaminal epidural steroid injection using different needle types

BACKGROUND Infrequent but serious complications of transforaminal epidural steroid injection (TFESI) occur due to inadvertent intravascular injections. A few studies reported that the different needle types can influence on the occurrences of intravascular incidence in TFESI. This study prospectively evaluated whether short-bevel needle can reduce the incidences of intravascular injection of TF...

متن کامل

Radiation exposure to the physician performing fluoroscopically guided caudal epidural steroid injections.

This study was designed to investigate radiation exposure to a physician performing fluoroscopically guided caudal epidural steroid injections. The prospective study design included 100 consecutive fluoroscopically guided caudal epidural steroid injections performed on patients with radiculitis from either herniated nucleus pulposus or lumbar spinal stenosis. Radiation exposure was monitored wi...

متن کامل

Factors Affecting Radiation Exposure during Lumbar Epidural Steroid Injection: A Prospective Study in 759 Patients

OBJECTIVE To estimate and compare radiation exposure and intervention time during lumbar epidural steroid injection (ESI) 1) under different practitioners and methods with continuous fluoroscopic monitoring, and 2) under one practitioner with different methods and monitoring. MATERIALS AND METHODS We consecutively recruited 804 patients who underwent lumbar ESI and 759 patients who underwent ...

متن کامل

Epidurography contrast patterns with fluoroscopic guided lumbar transforaminal epidural injections:a prospective evaluation.

BACKGROUND Lumbar transforaminal epidural injections have been utilized in the treatment of radicular pain with proven success. It was postulated that interlaminar epidural injections result in a dorsal flow of contrast while transforaminal epidural steroid injections showed good ventral flow limited to one single spinal motion segment. There have been no published studies evaluating epidurogra...

متن کامل

Digital Subtraction Angiography Use During Epidural Steroid Injections Does Not Reliably Distinguish Artery from Vein.

BACKGROUND Epidural steroid injections (ESIs) are among the most common procedures performed in an interventional pain management practice. It is well known that tragic complications may arise from ESIs, most commonly those performed using a transforaminal approach. Digital subtraction angiography (DSA) has been hailed as a fluoroscopic technique that can be used to detect arterial placement of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015