Reagentless amperometric immunosensor for human chorionic gonadotrophin based on direct electrochemistry of horseradish peroxidase.

نویسندگان

  • Jin Chen
  • Feng Yan
  • Zong Dai
  • Huangxian Ju
چکیده

A novel amperometric immunosensor for determination of human serum chorionic gonadotrophin (HCG) was constructed by immobilization of HCG with titania sol-gel on a glassy carbon electrode and the direct electrochemistry of horseradish peroxidase (HRP) labeled to HCG antibody (HRP-anti-HCG). The morphologies of the HCG membrane were characterized to be chemically clean, porous and homogeneous. HRP-anti-HCG was functionally conjugated with the immobilized HCG after incubation in phosphate buffer (PBS) containing HRP-anti-HCG. A direct electron transfer of HRP with a rate constant of 1.35+/-0.40 s(-1) was observed at the HRP-anti-HCG-HCG/titania sol-gel membrane modified electrode in 0.1 M PBS pH 7.0. With a competitive mechanism the differential pulse voltammetric peak current of the immobilized HRP decreased linearly with an increasing HCG concentration from 2.5 to 12.5 mIU/ml in the incubation solution. The HCG immunosensor showed a detection limit of 1.4 mIU/ml, a good accuracy and acceptable precision and reproducibility with an intra-assay CV of 4.7% at 5.0 mIU/ml and an inter-assay precision of 8.1% obtained at 10 mIU/ml. The biosensor displayed a good stability in a storage period of 30 days.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reagentless amperometric immunosensors based on direct electrochemistry of horseradish peroxidase for determination of carcinoma antigen-125.

A novel strategy for immunoassay and the preparation of reagentless immunosensors was proposed. This strategy was based on the immobilization of antigen and the direct electrochemistry of horseradish peroxidase (HRP) that was labeled to an antibody. A reagentless immunosensor for carcinoma antigen-125 (CA 125) determination was developed. The immunosensor was prepared by immobilizing CA 125 wit...

متن کامل

Amperometric immunosensors based on layer-by-layer assembly of gold nanoparticles and methylene blue on thiourea modified glassy carbon electrode for determination of human chorionic gonadotrophin.

Nano-Au and methylene blue (MB) were assembled layer-by-layer (LBL) into films on the glassy carbon electrode modified by thiourea for detection of human chorionic gonadotrophin (HCG). The electrode modification process was characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and scanning electron micrograph (SEM). The factors influencing the performance of the...

متن کامل

Disposable reagentless electrochemical immunosensor array based on a biopolymer/sol-gel membrane for simultaneous measurement of several tumor markers.

BACKGROUND A reagentless sensor array for simultaneous multianalyte testing (SMAT) may enable accurate diagnosis and be applicable for point-of-care testing. We developed a disposable reagentless immunosensor array for simple immunoassay of panels of tumor markers. METHODS We carried out SMAT with a direct capture format, in which colloidal gold nanoparticles with bound horseradish peroxidase...

متن کامل

Bacteria-modified amperometric immunosensor for a Brucella melitensis antibody assay.

A novel amperometric immunosensor setup is described which uses horseradish peroxidase (HRP) as a label in conjunction with a current-based Brucella sensor. The Bacteria modified immunosensor was constructed by using a biocomposite formed by dispersing graphite powder into a mixture of Brucella melitensis and silicate polymer gel. The enzyme-labeled antibody can readily diffuse toward the encap...

متن کامل

Fabrication of an Electrochemical Immunosensor for Determination of Human Chorionic Gonadotropin Based on PtNPs/Cysteamine/AgNPs as an Efficient Interface

An ultrasensitive electrochemical immunosensor for the detection of tumor marker human chorionic gonadotropin (hCG) was developed with a limit of detection as low as 2 pg mL-1 in phosphate buffer. The Platinum nanoparticles (PtNPs) were electrodeposited to modify the gold surface and to increase enlarging the electrochemically active sites, resulting in the facilitation of electron exchange. Cy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biosensors & bioelectronics

دوره 21 2  شماره 

صفحات  -

تاریخ انتشار 2005