Intracochlear Position of Cochlear Implants Determined Using CT Scanning versus Fitting Levels: Higher Threshold Levels at Basal Turn.

نویسندگان

  • Feddo B van der Beek
  • Jeroen J Briaire
  • Kim S van der Marel
  • Berit M Verbist
  • Johan H M Frijns
چکیده

OBJECTIVES In this study, the effects of the intracochlear position of cochlear implants on the clinical fitting levels were analyzed. DESIGN A total of 130 adult subjects who used a CII/HiRes 90K cochlear implant with a HiFocus 1/1J electrode were included in the study. The insertion angle and the distance to the modiolus of each electrode contact were determined using high-resolution CT scanning. The threshold levels (T-levels) and maximum comfort levels (M-levels) at 1 year of follow-up were determined. The degree of speech perception of the subjects was evaluated during routine clinical follow-up. RESULTS The depths of insertion of all the electrode contacts were determined. The distance to the modiolus was significantly smaller at the basal and apical cochlear parts compared with that at the middle of the cochlea (p < 0.05). The T-levels increased toward the basal end of the cochlea (3.4 dB). Additionally, the M-levels, which were fitted in our clinic using a standard profile, also increased toward the basal end, although with a lower amplitude (1.3 dB). Accordingly, the dynamic range decreased toward the basal end (2.1 dB). No correlation was found between the distance to the modiolus and the T-level or the M-level. Furthermore, the correlation between the insertion depth and stimulation levels was not affected by the duration of deafness, age at implantation or the time since implantation. Additionally, the T-levels showed a significant correlation with the speech perception scores (p < 0.05). CONCLUSIONS The stimulation levels of the cochlear implants were affected by the intracochlear position of the electrode contacts, which were determined using postoperative CT scanning. Interestingly, these levels depended on the insertion depth, whereas the distance to the modiolus did not affect the stimulation levels. The T-levels increased toward the basal end of the cochlea. The level profiles were independent of the overall stimulation levels and were not affected by the biographical data of the patients, such as the duration of deafness, age at implantation or time since implantation. Further research is required to elucidate how fitting using level profiles with an increase toward the basal end of the cochlea benefits speech perception. Future investigations may elucidate an explanation for the effects of the intracochlear electrode position on the stimulation levels and might facilitate future improvements in electrode design.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multisection CT as a valuable tool in the postoperative assessment of cochlear implant patients.

A data acquisition protocol for postoperative imaging of cochlear implants by using multisection CT (MSCT) is described. The improved image quality of MSCT allows assessment of the precise intracochlear position of the electrode array and visualization of individual electrode contacts. Such images can aid in fitting the speech processor, especially in difficult cases.

متن کامل

Intracochlear factors contributing to psychophysical percepts following cochlear implantation.

The performance of cochlear implant patients may be related to intracochlear, histopathological factors. We have performed detailed post-mortem examinations of five human, implanted cochleas and for each electrode correlated the psychophysical threshold, comfortable level and dynamic range with spiral ganglion cell survival, presence of fibrous tissue and/or new bone, and distance between the c...

متن کامل

Longitudinal variations in fitting parameters for adult cochlear implant recipients

In patients with a cochlear implant (CI), the first critical point in processing auditory information from sound stimuli that leads to comprehension is the interface between the electrode and the cochlear nerve, which is dependent on providing appropriate current input. The purpose of this work was to evaluate the longitudinal differences in psychoacoustic fitting parameters in CI users. We stu...

متن کامل

Radiologic and functional evaluation of electrode dislocation from the scala tympani to the scala vestibuli in patients with cochlear implants.

BACKGROUND AND PURPOSE Localization of the electrode after cochlear implantation seems to have an impact on auditory outcome, and conebeam CT has emerged as a reliable method for visualizing the electrode array position within the cochlea. The aim of this retrospective study was to evaluate the frequency and clinical impact of scalar dislocation of various electrodes and surgical approaches and...

متن کامل

3D curved multiplanar cone beam CT reconstruction for intracochlear position assessment of straight electrodes array. A temporal bone and clinical study

A retrospective review of post-op cone beam CT (CBCT) of 8 adult patients and 14 fresh temporal bones that underwent cochlear implantation with straight flexible electrodes array was performed to determine if the position of a long and flexible electrodes array within the cochlear scalae could be reliably assessed with CBCT. An oto-radiologist and two otologists examined the images and assessed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Audiology & neuro-otology

دوره 21 1  شماره 

صفحات  -

تاریخ انتشار 2016