Magnetization transfer contrast imaging of hepatic neoplasms.
نویسندگان
چکیده
A method of performing magnetization transfer contrast (MTC) using a pulse sequence based on a series of on-resonance binomial pulses preceding a conventional spin-echo sequence has been recently described. We investigated this technique in the evaluation of circumscribed hepatic neoplasms on a 0.5 T imager. Conventional spin-echo imaging was performed in 18 patients with hepatic neoplasms, 15 with primary or metastatic hepatic neoplasms, and 3 with cavernous hemangiomas. The T1-weighted sequence was repeated following MTC saturation in 7 patients and the proton density sequence was repeated following MTC saturation in 13 patients (both were used in two patients). The mean lesion-to-liver contrast for neoplasms worsened with T1-MTC (0.87 vs. 1.04), but improved slightly with proton density-MTC (1.10 vs. 1.22) when compared to the corresponding non-MTC spin-echo images. However, these differences were not statistically significant (p = .19 and p = .16, respectively). The limited data on cavernous hemangiomas does not suggest these have consistently different MTC imaging characteristics from other hepatic neoplasms. In conclusion, MTC imaging using a binomial saturation pulse did not offer significant improvement in contrast between hepatic neoplasms and normal liver. Refinements of the binomial pulse sequence will be necessary if a consistent improvement in lesion sensitivity is to be achieved. Evaluation of its role in increasing diagnostic specificity will require further investigation.
منابع مشابه
Analytical determination of the chemical exchange saturation transfer (CEST) contrast in molecular magnetic resonance imaging
Magnetic resonance based on molecular imaging allows tracing contrast agents thereby facilitating early diagnosis of diseases in a non-invasive fashion that enhances the soft tissue with high spatial resolution. Recently, the exchange of protons between the contrast agent and water, known as the chemical exchange saturation transfer (CEST) effect, has been measured by applying a suitable pulse ...
متن کاملMR of intracranial tumors: combined use of gadolinium and magnetization transfer.
PURPOSE To study the potential combined application of gadolinium and magnetization transfer in the MR imaging of intracranial tumors. METHODS Twenty-two patients were imaged at low field strength (0.1 T). Corresponding gradient-echo partial saturation images without and with magnetization transfer pulse were produced. Images with intermediate repetition times were obtained in 18 cases; five ...
متن کاملF-18 FDG PET/CT imaging of primary hepatic neuroendocrine tumor
Primary hepatic neuroendocrine tumors (PHNETs) are extremely rare neoplasms. Herein, we report a case of a 70-year-old man with a hepatic mass. The non-contrast computed tomography (CT) image showed a low-density mass, and dynamic CT images indicated the enhancement of the mass in the arterial phase and early washout in the late phase. F18- fluorodeoxyglucose (18F-FDG) positron emission tomogra...
متن کاملA Novel Classification Method using Effective Neural Network and Quantitative Magnetization Transfer Imaging of Brain White Matter in Relapsing Remitting Multiple Sclerosis
Background: Quantitative Magnetization Transfer Imaging (QMTI) is often used to quantify the myelin content in multiple sclerosis (MS) lesions and normal appearing brain tissues. Also, automated classifiers such as artificial neural networks (ANNs) can significantly improve the identification and classification processes of MS clinical datasets.Objective: We classified patients with relapsing-r...
متن کاملPathological Assessment of Brain White Matter in Relapsing-Remitting MS Patients using Quantitative Magnetization Transfer Imaging
Introduction: Multiple sclerosis (MS) is characterized by lesions in the white matter (WM) of the central nervous system. Magnetic resonance imaging is the most specific and sensitive method for diagnosis of multiple sclerosis. However, the ability of conventional MRI to show histopathologic heterogeneity of MS lesions is insufficient. Quantitative magnetization transfer imaging (qMTI) is a rel...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance imaging
دوره 12 1 شماره
صفحات -
تاریخ انتشار 1994