Accuracy of implant impressions with different impression coping types and shapes.

نویسندگان

  • Nayereh Rashidan
  • Marzieh Alikhasi
  • Samad Samadizadeh
  • Elahe Beyabanaki
  • Mohammad Javad Kharazifard
چکیده

BACKGROUND Accurate recording of implant location is required so that definitive restorations are properly supported and do not place additional stresses on the implants. Movement of impression copings inside the impression material using an open-tray or close-tray impression technique during clinical and laboratory phases may cause inaccuracy in transferring the three-dimensional spatial orientation of implants intraorally to the definitive cast. Consequently, the restoration may require corrective procedures. AIM This in vitro study compared the accuracy of two different impression techniques with two different impression coping shapes using polyether impression material to obtain precise definitive casts. MATERIALS AND METHODS Two reference acrylic resin models (Technovits 4000, Heraeus Kulzer GmbH & Co., Wehrheim, Germany) with five internal connection implants having different shapes of impression copings (Implantium [Dentium, Seoul, South Korea] and Replace Select [Nobel Biocare AB, Göteborg, Sweden]) were fabricated. Twenty medium-consistency polyether impressions of these models were made with square and conical impression copings of each system using open-tray and close-tray techniques. Matching implant replicas were screwed into the impression copings in the impressions. Impressions were poured with type IV stone, and the positional accuracy of the implant replica heads in x-, y-, and z-axes (represented in [Δr]) and also rotational displacement (ΔΘ) were evaluated using a coordinate measuring machine (Mistral, DEA Brown&Sharpe, Grugliasco, Italy). These measurements (linear and rotational displacements) were compared with the measurements calculated on the reference resin models that served as control, and data were analyzed with a two-way analysis of variance at α = 0.05. RESULTS Less inaccuracy occurred in less retentive shape impression copings (Replace Select) compared with the more retentive one (Implantium) (p(r) < .001 and p(Θ) < .001), but there was no significant difference between direct and indirect impression techniques (p(r) and p(Θ) > .05). CONCLUSION The impression coping shape had more impact on impression inaccuracy than impression technique did. Understanding of the magnitude and variability of distortion when employing certain impression-making methods and impression coping shapes helps the clinician to select a better implant component and impression technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study

PURPOSE The purpose of this study was to compare the accuracy of the implant master cast according to the type (pick-up, transfer) and the length (long, short) of the impression copings. MATERIALS AND METHODS The metal master cast was fabricated with three internal connection type implant analogs (Osstem GS III analog), embedded parallel and with 10° of mesial angulation to the center analog....

متن کامل

تعیین دقت ثبت ایمپلنت و جزئیات سطحی با استفاده از پلی‌اتر و پلی‌وینیل سایلوکسان با روش تری بسته

  Background and Aims: Making accurate impressions of prepared teeth when they are adjacent to dental implants is of great importance. In these situations, disregarding the selection of appropriate impression material and technique, not only can affect accuracy of transferring of the 3-dimentional spatial status of implant, but also can jeopardize the accurate recording of tooth. In the present...

متن کامل

Comparative Analysis of Dimensional Accuracy of Two Types of Silicone Impression Materials: Optosil and Elite-HD

Statement of the Problem: Understanding about impression materials, their properties, uses and manipulation can guide operators towards having more successful restorations. Purpose: The aim of this in vitro study was to compare the accuracy of a condensation silicone impression material, Optosil, and an addition poly siloxane impression material, Elite-HD. Materials and Method: A laboratory mod...

متن کامل

Effect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in vitro comparative study.

BACKGROUND With regard to implant-supported prostheses, to date no technique has been proven to guarantee a completely passive fit of prosthetic frameworks. Several clinical variables may affect the precision of impressions, particularly in the presence of implants. PURPOSE To compare the accuracy of implant impressions made with different materials, lengths of impression coping connections, ...

متن کامل

The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap

Statement of the Problem Precision of the impression taken from implant positions significantly determines accurate fit of implant-supported prostheses. An imprecise impression may produce prosthesis misfit. Purpose This study aimed to evaluate the accuracy of four impression-making techniques for angulated implants by stereomicroscope through measuring the vertical marginal gaps between the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical implant dentistry and related research

دوره 14 2  شماره 

صفحات  -

تاریخ انتشار 2012