Intra-aneurysmal pressure measurements in experimental saccular aneurysms in dogs.

نویسندگان

  • L N Sekhar
  • R J Sclabassi
  • M Sun
  • H B Blue
  • J F Wasserman
چکیده

Intra-aneurysmal pressure was studied in an experimental model of saccular aneurysm in dogs, using a vein pouch grafted onto a common carotid arterial bifurcation. The mean and the pulse pressures were recorded simultaneously from within the aneurysm and within the common carotid artery, before and after 50% proximal carotid artery stenosis. These experiments were performed under systemic normotension, hypotension, and hypertension. Normal data suggest that mean intracarotid and intra-aneurysmal pressures are similar and relate in a nearly linear fashion to mean arterial pressure. However, after 50% stenosis, the data had a cubic relationship, the reduction of pressure occurring only in the middle range of mean arterial pressure. Both intra-aneurysmal and intracarotid pulse pressures displayed less dependence on mean arterial pressure. However, sigmoid curves also were observed with the pulse pressures after 50% proximal common carotid artery stenosis. In all cases, after 50% stenosis, the rate of increase of the pulse pressures with mean arterial pressure was greater for higher mean arterial pressures. Our preliminary data indicate that a detailed study of intra-aneurysmal pressure and blood flow in relation to systemic variables such as mean arterial pressure, cardiac output, and peripheral resistance may not only suggest improved means of managing patients with intracranial aneurysms, but also may raise the possibility that, under certain conditions, higher intra-aneurysmal pressures may be induced by downstream stenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acoustic recordings from experimental saccular aneurysms in dogs.

In an effort to isolate and characterize the emission of acoustic signals from saccular aneurysms, we made a series of invasive microphone recordings from experimental aneurysms created on the common carotid arteries of dogs using the vein pouch technique. Using a modified probe microphone, we compared recordings from the common carotid artery before creation of the aneurysm to recordings from ...

متن کامل

Intra-aneurysmal pressure and flow changes induced by flow diverters: relation to aneurysm size and shape.

BACKGROUND AND PURPOSE Effects of blood flow modification by flow diverters are observed to lead often to aneurysm thrombosis and reverse remodeling. For this process, to further understand the potential roles of intra-aneurysmal blood pressure changes and aneurysm morphologies, 23 patients were studied by numeric simulation. MATERIALS AND METHODS 3D imaging of aneurysms of different sizes an...

متن کامل

Cerebral aneurysms treated with flow-diverting stents: computational models with intravascular blood flow measurements.

BACKGROUND AND PURPOSE Computational fluid dynamics modeling is useful in the study of the hemodynamic environment of cerebral aneurysms, but patient-specific measurements of boundary conditions, such as blood flow velocity and pressure, have not been previously applied to the study of flow-diverting stents. We integrated patient-specific intravascular blood flow velocity and pressure measureme...

متن کامل

Effect of intraluminal thrombus on pressure transmission in the abdominal aortic aneurysm.

OBJECTIVE To clarify the effect of intraluminal thrombus on pressure transmission. METHODS A saccular aneurysm was inserted into an artificial circulation system. Subsequently, the saccular aneurysm was filled with eight different human aortic aneurysm thrombus samples. Starch solution in an empty aneurysm was used as a control. A pressure sensor measured the pressure in the circulation, and ...

متن کامل

Noninvasive measurement of intra-aneurysmal pressure and flow pattern using phase contrast with vastly undersampled isotropic projection imaging.

BACKGROUND AND PURPOSE Currently, more reliable parameters to predict the risk of aneurysmal rupture are needed. Intra-aneurysmal pressure gradients and flow maps could provide additional information regarding the risk of rupture. Our hypothesis was that phase contrast with vastly undersampled isotropic projection reconstruction (PC-VIPR), a novel 3D MR imaging sequence, could accurately assess...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 19 3  شماره 

صفحات  -

تاریخ انتشار 1988