Apparent latent heat of evaporation from clothing: attenuation and "heat pipe" effects.

نویسندگان

  • George Havenith
  • Mark G Richards
  • Xiaoxin Wang
  • Peter Bröde
  • Victor Candas
  • Emiel den Hartog
  • Ingvar Holmér
  • Kalev Kuklane
  • Harriet Meinander
  • Wolfgang Nocker
چکیده

Investigating claims that a clothed person's mass loss does not always represent their evaporative heat loss (EVAP), a thermal manikin study was performed measuring heat balance components in more detail than human studies would permit. Using clothing with different levels of vapor permeability and measuring heat losses from skin controlled at 34 degrees C in ambient temperatures of 10, 20, and 34 degrees C with constant vapor pressure (1 kPa), additional heat losses from wet skin compared with dry skin were analyzed. EVAP based on mass loss (E(mass)) measurement and direct measurement of the extra heat loss by the manikin due to wet skin (E(app)) were compared. A clear discrepancy was observed. E(mass) overestimated E(app) in warm environments, and both under and overestimations were observed in cool environments, depending on the clothing vapor permeability. At 34 degrees C, apparent latent heat (lambda(app)) of pure evaporative cooling was lower than the physical value (lambda; 2,430 J/g) and reduced with increasing vapor resistance up to 45%. At lower temperatures, lambda(app) increases due to additional skin heat loss via evaporation of moisture that condenses inside the clothing, analogous to a heat pipe. For impermeable clothing, lambda(app) even exceeds lambda by four times that value at 10 degrees C. These findings demonstrate that the traditional way of calculating evaporative heat loss of a clothed person can lead to substantial errors, especially for clothing with low permeability, which can be positive or negative, depending on the climate and clothing type. The model presented explains human subject data on EVAP that previously seemed contradictive.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Entropy Generation Through the Operation of an Unlooped Pulsating Heat Pipe

In the present study, an unlooped pulating heat pipe has been considered with two liquid slugs and three neighboirng vapor plugs.The governing equations such as momentum, energy and mass equations are solved explicitly except the energy equation of liquid slugs.The aim of the present study is to calculate the entropy generation through the performance of a pulsating heat pipe. Additionally, the...

متن کامل

Evaporative cooling: effective latent heat of evaporation in relation to evaporation distance from the skin.

Calculation of evaporative heat loss is essential to heat balance calculations. Despite recognition that the value for latent heat of evaporation, used in these calculations, may not always reflect the real cooling benefit to the body, only limited quantitative data on this is available, which has found little use in recent literature. In this experiment a thermal manikin, (MTNW, Seattle, WA) w...

متن کامل

PCM storage system with integrated active heat pipe

The use of the latent heat of phase change materials (PCM) is considered a promising approach to store heat at a nearly constant temperature for direct steam generation (DSG), but the poor thermal conductivity of commonly available storage materials imposes severe limitations on storage performance. A new method is proposed to overcome the limitations of the low thermal conductivity. The approa...

متن کامل

Dry and wet heat transfer through clothing dependent on the clothing properties under cold conditions.

The purpose of this study was to investigate the effect of moisture on the heat transfer through clothing in relation to the water vapour resistance, type of underwear, location of the moisture and climate. This forms part of the work performed for work package 2 of the European Union THERMPROTECT project. Thermal manikin results of dry and wet heat loss are presented from different laboratorie...

متن کامل

Flat Miniature Heat Pipes for Electronics Cooling: State of the Art, Experimental and Theoretical Analysis

An experimental study is realized in order to verify the Mini Heat Pipe (MHP) concept for cooling high power dissipation electronic components and determines the potential advantages of constructing mini channels as an integrated part of a flat heat pipe. A Flat Mini Heat Pipe (FMHP) prototype including a capillary structure composed of parallel rectangular microchannels is manufactured and a f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 104 1  شماره 

صفحات  -

تاریخ انتشار 2008