A Micro Saddle Coil with Switchable Sensitivity for Local High-Resolution Imaging of Luminal Tissue
نویسندگان
چکیده
This paper reports on a micro saddle coil for local high-resolution magnetic resonance imaging (MRI) fabricated by embedding a flexible coil pattern into a polydimethyilsiloxane (PDMS) tube. We can change the sensitivity of the micro coil by deforming the shape of the coil from a saddle-shaped mode to a planar-shaped mode. The inductance, the resistance, and the Q-factor of the coil in the saddle-shaped mode were 2.45 μH, 3.31 Ω, and 39.9, respectively. Those of the planar-shaped mode were 3.07 μH, 3.92 Ω, and 42.9, respectively. In MRI acquired in saddle-shaped mode, a large visible area existed around the coil. Although the sensitive area was considerably reduced in the planar-shaped mode, clear MRI images were obtained. The signal-to-noise ratios (SNR) of the saddle-shaped and planar-shaped modes were 194.9 and 505.9, respectively, at voxel size of 2.0 ˆ 2.0 ˆ 2.0 mm3 and 11.7 and 37.4, respectively, at voxel size of 0.5 ˆ 0.5 ˆ 1.0 mm3. The sensitivity of the saddle-shaped and the planar-shaped modes were about 3 times and 10 times higher, respectively, than those of the medical head coil at both voxel sizes. Thus, the micro saddle coil enabled large-area imaging and highly sensitive imaging by switching the shape of the coil.
منابع مشابه
Switchable multicoil array for MR micro-imaging of breast lesions.
High-resolution breast imaging may improve differentiation between benign and malignant lesions and may be important for refining treatment strategy. This article presents a new, flexible design of a breast-imaging coil capable of providing breast images of a high level of spatial resolution. Referred to as a switchable coil array, the design uses small-diameter surface coils that provide high ...
متن کاملEffect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI
Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...
متن کاملHigh-resolution 3D isotropic MR imaging of mouse flank tumours obtained in vivo with solenoid RF micro-coil.
The investigation of mouse flank tumours by magnetic resonance imaging (MRI) is limited by the achievable spatial resolution, which is generally limited by the critical problem of signal-to-noise ratio. Sensitivity was improved by using an optimized solenoid RF micro-coil, built into the animal cradle. This simple design did not require extensive RF engineering expertise to construct, yet allow...
متن کاملNoninvasive Stem Cell Labeling Using USPIO Technique and their Detection with MRI
Background: To date, several imaging techniques to track stem cells are used such as positron emission tomography (PET), single photon emission computed tomography (SPECT), Bioluminescence imaging (BLI), fluorescence imaging, CT scan and magnetic resonance imaging (MRI). Although, overall sensitivity of MRI compared to SPECT and Bioluminescence techniques are lower, but due to high spatial reso...
متن کاملMulti-coil MR imaging with a receive array of eight microcoils
Introduction Three-dimensional microcoils are used in medical technology for high-resolution magnetic resonance analysis at the micro level. The coil sensitivity, and therefore the desired signal, is maximized when the size of the coil matches that of the sample [1]. Micro solenoids show exceptional performance compared to planar coils and due to their 3-D shape, the B1 field is stronger and mo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Micromachines
دوره 7 شماره
صفحات -
تاریخ انتشار 2016