Evaluation of implant alignment in navigated unicompartmental knee arthroplasty: a comparison of 2D and 3D imaging.
نویسندگان
چکیده
This study aimed to compare two-dimensional (2D) and three-dimensional (3D) methods for evaluating implant alignment in navigated UKA. Nineteen UKAs in 18 subjects (7 men) were performed using an image-free navigation system. Coronal and sagittal implant alignments were assessed using radiographs (2D evaluation) and 3D image-matching software. The accuracy of 2D evaluation was compared with that of 3D evaluation. A deviation > 3° from the 3D evaluation was defined as an outlier. In the 2D evaluation, outliers for the femoral component were observed in both the coronal plane (6/19 subjects) and the sagittal plane (3/19 subjects). In UKA, assessment of the implant position might be misjudged because of the design of the implant, especially for the femoral component; 3D methods are ideal for assessment of implant alignment.
منابع مشابه
Inaccurate rotational component position in image-free navigated unicompartmental knee arthroplasty
Background/Objective The success of unicompartmental knee arthroplasty (UKA) is highly dependent on the accuracy of component and leg alignment. Computer-assisted surgery is gaining popularity in total knee arthroplasty with numerous studies reporting improved accuracy and decreased variability in implant position and postoperative limb alignment compared with conventional techniques. However, ...
متن کاملNavigated shorter incision or smaller implant in knee arthritis?
Minimally invasive approaches for unicompartmental knee arthroplasty are well-accepted for treating knee arthritis because of the smaller implant size, shorter operative time, and tissue-sparing nature of the procedure. With the introduction of computer alignment systems, a well-aligned and balanced total knee arthroplasty (TKA) can be achieved even with smaller surgical exposures. We hypothesi...
متن کاملUnicompartmental Knee Osteoarthritis (UKOA): Unicompartmental Knee Arthroplasty (UKA) or High Tibial Osteotomy (HTO)?
Background: The aim of this review article is to analyze the results of high tibial osteotomy compared to unicompartmental knee arthroplasty in patients with unicompartmental knee osteoarthritis. Methods: The search engine used was PubMed. The keywords were: "high tibial osteotomy versus unicompartmental knee arthroplasty". Twenty-one articles were found on 28 February 2015, but only eighte...
متن کاملDeviation between navigated and final 3-dimensional implant position in mini-invasive unicompartmental knee arthroplasty
BACKGROUND AND PURPOSE Unicompartmental knee arthroplasty (UKA) is an established method of treating isolated gonartrosis. Modern techniques such as computer-assisted surgery (CAS) and minimally invasive surgery (MIS) are attractive complementary methods to UKA. However, the positioning of the components remains a concern. Thus, we performed a prospective study to assess whether there was devia...
متن کاملLimb alignment in computer-assisted minimally-invasive unicompartmental knee replacement.
Twenty patients underwent simultaneous bilateral medial unicompartmental knee arthroplasty. Pre-operative hip-knee-ankle alignment and valgus stress radiographs were used to plan the desired post-operative alignment of the limb in accordance with established principles for unicompartmental arthroplasty. In each patient the planned alignment was the same for both knees. Overall, the mean planned...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica Belgica
دوره 81 4 شماره
صفحات -
تاریخ انتشار 2015