Critical Analysis of Non-Nuclear Electron-Density Maxima and the Maximum Entropy Method.

نویسندگان

  • de Vries RY
  • Briels
  • Feil
چکیده

Experimental evidence for the existence of non-nuclear maxima in charge densities is questioned. It is shown that the non-nuclear maxima reported for silicon are artifacts of the maximum entropy method that was used to analyze the x-ray diffraction data. This method can be improved by the use of appropriate prior information. We report systematic tests of the improved method leading to the absence of non-nuclear maxima in Si. Likewise, the non-nuclear maxima reported earlier in beryllium are not substantiated. [S0031-9007(96)01044-7]

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Charge density study with the Maximum Entropy Method on model data

In 1990 Sakata and Sato applied the maximum entropy method (MEM) to a set of structure factors measured earlier by Saka and Kato with the Pendellosung method. They found the presence of non-nuclear attractors, i.e., maxima in the density between two bonded atoms. We applied the MEM to a limited set of Fourier data calculated from a known electron density distribution (EDD) of silicon. The EDD o...

متن کامل

محاسبات توماس- فرمی برای تعیین خواص بحرانی ماده هسته‌ای متقارن براساس رهیافت جرم مؤثر تعمیم‌یافته

Using mean-field and semi-classical approximation of Thomas-Fermi, within a statistical model, equation of state and critical properties of symmetric nuclear matter is studied.  In this model, two body and phenomenological interaction of Myers and Swiatecki is used in phase space. By performing  a functional variation of the total Helmholtz free energy of system with respect to the nucleonic di...

متن کامل

Imagi,ng of Diffraction Data by the Maximum Entropy Method -anew Approach to Crystallography-

The recent works of the Maximum Entropy Method (MEM) in the field of accurate crystal structure analysis were reviewed, The role of MEM analysis in these works are described by the concept of Imaging of Diffraction Data (IDD). Assuming that the phase problem is solved by direct method or some other way, it is possible to construct the real space image, such as the electron density distribution ...

متن کامل

Feasibility of using statistical tests in evaluation of non-uniformity [Persian]

Introduction: Non-uniformity test is essentially the only required daily QC procedure in nuclear medicine practice. Noise creates statistical variation or random error in a flood image. Non-uniformity on the other hand does not have statistical nature and may be regarded as systemic error. The present methods of non-uniformity calculation do not distinguish between these two types of erro...

متن کامل

Tomographic Reconstruction of the Ionospheric Electron Density in term of Wavelets

Ionospheric tomography is a method to investigate the ionospheric electron density in two or three dimensions. In this study, the function-based tomographic technique has been used for regional reconstruction of a 3D tomographic model of the ionospheric electron density using the GPS measurements of the Iranian Permanent GPS Network. Two-dimensional Haar wavelets and empirical orthogonal functi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physical review letters

دوره 77 9  شماره 

صفحات  -

تاریخ انتشار 1996