Performance of an Optimized Paper-Based Test for Rapid Visual Measurement of Alanine Aminotransferase (ALT) in Fingerstick and Venipuncture Samples
نویسندگان
چکیده
BACKGROUND A paper-based, multiplexed, microfluidic assay has been developed to visually measure alanine aminotransferase (ALT) in a fingerstick sample, generating rapid, semi-quantitative results. Prior studies indicated a need for improved accuracy; the device was subsequently optimized using an FDA-approved automated platform (Abaxis Piccolo Xpress) as a comparator. Here, we evaluated the performance of the optimized paper test for measurement of ALT in fingerstick blood and serum, as compared to Abaxis and Roche/Hitachi platforms. To evaluate feasibility of remote results interpretation, we also compared reading cell phone camera images of completed tests to reading the device in real time. METHODS 96 ambulatory patients with varied baseline ALT concentration underwent fingerstick testing using the paper device; cell phone images of completed devices were taken and texted to a blinded off-site reader. Venipuncture serum was obtained from 93/96 participants for routine clinical testing (Roche/Hitachi); subsequently, 88/93 serum samples were captured and applied to paper and Abaxis platforms. Paper test and reference standard results were compared by Bland-Altman analysis. FINDINGS For serum, there was excellent agreement between paper test and Abaxis results, with negligible bias (+4.5 U/L). Abaxis results were systematically 8.6% lower than Roche/Hitachi results. ALT values in fingerstick samples tested on paper were systematically lower than values in paired serum tested on paper (bias -23.6 U/L) or Abaxis (bias -18.4 U/L); a correction factor was developed for the paper device to match fingerstick blood to serum. Visual reads of cell phone images closely matched reads made in real time (bias +5.5 U/L). CONCLUSIONS The paper ALT test is highly accurate for serum testing, matching the reference method against which it was optimized better than the reference methods matched each other. A systematic difference exists between ALT values in fingerstick and paired serum samples, and can be addressed by application of a correction factor to fingerstick values. Remote reading of this device is feasible.
منابع مشابه
A paper-based multiplexed transaminase test for low-cost, point-of-care liver function testing.
In developed nations, monitoring for drug-induced liver injury through serial measurements of serum transaminases [aspartate aminotransferase (AST) and alanine aminotransferase (ALT)] in at-risk individuals is the standard of care. Despite the need, monitoring for drug-related hepatotoxicity in resource-limited settings is often limited by expense and logistics, even for patients at highest ris...
متن کاملField Evaluation of a Prototype Paper-Based Point-of-Care Fingerstick Transaminase Test
Monitoring for drug-induced liver injury (DILI) via serial transaminase measurements in patients on potentially hepatotoxic medications (e.g., for HIV and tuberculosis) is routine in resource-rich nations, but often unavailable in resource-limited settings. Towards enabling universal access to affordable point-of-care (POC) screening for DILI, we have performed the first field evaluation of a p...
متن کاملIs Quantitative HBsAg Measurement a Reliable Substitute for HBV DNA Quantitation?
Background: Hepatitis B surface antigen (HBsAg) is one of the main proteins of HBV envelop and its serum quantitative measurement is the most common quantitative test for monitoring the progress of Chronic Hepatitis B. Although measurement of serum HBV DNA copy number is a gold standard method for displaying viral load, the test is relatively expensive and it is not readily available everywhere...
متن کاملاثرات 4 هفته بیتمرینی به دنبال 12 هفته تمرینهای هوازی بر تغییرات آلانین آمینوترانسفراز، آسپارتات آمینوترانسفراز، آلکالین فسفاتاز و سطح چربیهای خون در موشهای یائسه
Background and Objectives : Previous studies confirm the effects of strenuous exercise on elevated levels of liver enzymes, but the effect of detraining especially on liver tissue enzymes is unclear. The purpose of this study was to examine the effects of a 12-week aerobic training course followed by a 4-week detraining period on on liver tissue enzymes including Alanine aminotransferase(ALT)...
متن کاملبررسی عوارض ناشی از مصرف استروئیدهای آنابولیک-آندروژنیک بر آنزیمهای کبدی (ALT، AST، ALP) و فاکتورهای هماتولوژیک سرمی در مردان ورزشکار رشتهی پرورش اندام
Background and Objective: Effort for improving athletic function makes athletes use stimulants. The aim of the present study was to investigate the effects of consuming steroids on liver enzymes and blood factors in male bodybuilders. Materials and Methods: Ex post facto design comprising 48 male bodybuilders (age 25.02 ± 4.73 years old, weight 80.75 ± 6.33 kg) were assigned to three groups...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2015