Iotrol, a new myelographic agent: 2. Comparative electroencephalographic evaluation by spectrum analysis.
نویسندگان
چکیده
Iotrol, a nonionic dimer isotonic with cerebrospinal fluid at 300 mg l/ml, was evaluated against metrizamide, iopamidol, and iohexol by electroencephalography (EEG) in nonanesthetized cynomolgus monkeys. Each of four monkeys was injected intrathecally with 0.5 ml/kg of 300 mg l/ml of each contrast medium. EEG was obtained before, 45 min, and 3 hr postinjection. EEG spikes, motor disturbances, convulsions, and behavior changes were observed. The EEG from C3 channel was also computer-analyzed. Average percentage differences between control and test energy content of the entire EEG and of the EEG spectrum subdivided into five frequency bands were calculated. With metrizamide, three animals suffered seizures, and all were lethargic and irritable. With iopamidol, two animals convulsed; all animals were lethargic. Transient apathy and motor disturbances were observed in the iohexol animals. No motor or behavior changes were produced by iotrol. Metrizamide and iopamidol increased the spectrum energy in all bands. Neither iohexol nor iotrol affected the EEG significantly. On the basis of these findings, iotrol holds promise as a clinical contrast material for the subarachnoid space.
منابع مشابه
Iotrol, a new myelographic agent: 1. Radiography, CT, CSF clearance, and brain penetration.
Four new myelographic agents, metrizamide, iopamidol, iohexol, and iotrol, were studied in the subarachnoid space of cynomolgus monkeys. Plain films and computed tomographic scans documented the transport of each material throughout the space and into the brain. At the concentration used (300 mg I/ml), all gave good radiopacity for myelography and delineation of the cerebral subarachnoid space....
متن کاملlotrol, lodixanol, and 2-Deoxy-o- Giucose Effects on Neural Tissue
In vivo and in vitro experiments have demonstrated that the myelographic agent metrizamide decreases neural tissue glucose metabolism whereas iohexol and iopamidol do not. This study compares the changes in slices of rat hippocampus C02 production caused by the nonionic dimers iotrol and iodixanol with the effects of metrizamide and 2-deoxy-o-glucose. After 6-hr incubations, 70-mmolfl concentra...
متن کاملNeurotoxicity of nonionic iodinated water-soluble contrast media in myelography: experimental study.
The neurotoxicity of four contrast media--iotrol, iopamidol, metrizamide, and ioglunide--was studied by subarachnoid injection in 14 rabbits implanted with four cerebral electrodes. Thirty-four recordings and quantitative analyses were carried out of spontaneous electrical brain activity, seizure activity, and visual- and somatosensory-evoked potentials. The quantitative study of the electroenc...
متن کاملClinical trial of iotrol for lumbar myelography.
Iotrol, a new nonionic, water-soluble, hexiodinated dimeric contrast medium for myelography, was used in clinical trials in 29 patients. The purpose of the study was to acquire information on local and general tolerance, distribution and excretion, and image quality. Preliminary results show that iotrol is well suited for lumbar and thoracolumbar myelography. Side effects observed with the use ...
متن کاملA Feasible Solution to Distinguish the Transformer Winding Deformation from Insulation Characteristic Impacts on FRA Spectrum
Frequency Response Analysis (FRA) is popular technique which has been used since the last decade as a diagnostic method for transformers. However, accurate interpretation of FRA measurements is still challenging. Recent studies reveal that apart from winding deformation, FRA data can also be influenced by moisture variation in transformer paper insulation. Hence, a specific transformer’s model ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 4 3 شماره
صفحات -