Design and Analysis of an Electromagnetically Driven Valve for a Glaucoma Implant
نویسندگان
چکیده
|Glaucoma is an eye disease which is caused by abnormal high IOP (Intra Ocular Pressure) in the eye. The use of implants is increasing in these days in order to treat the glaucoma. However, though conventional implants have a capability of pressure regulation, they cannot maintain IOPs desired for di erent patients. To solve these problems, it is needed to develop a new implant which is capable of controlling the IOP actively and copes with the personal di erence of patients. An active glaucoma implant consists of the valve actuator, pressure sensor, controller, and power supply. In this paper, rstly, we make an analysis of the operation of the conventional implant using a bond graph, and show its defects and limitations of the conventional valve analytically. Secondly, we design and analyze an electromagnetically driven valve actuator composed of membrane, air-core solenoid, permanent magnet, and covering frame. To save the electrical power for operating the valve actuator, appropriate actuating methods are suggested and an optimal design of the valve actuator is carried out. Finally, using simulations, the possibility of the proposed valve actuator is investigated. Keywords|glaucoma, IOP, glaucoma implant, valve actuator
منابع مشابه
Using Ahmed’s Gonioimplant Valve to Surgical Treatment of Glaucoma in Two Dogs
Case Description- An eleven-year-old Golden retriever male dog (dog I) and a four-year-old neutered Toy Terrier (dog II) were referred to Small Animal Clinic. Dog I was suffered from partial loss of vision and engorgement of episcleral vessels of his right eye and dog II was blind. Intraocular pressure (IOP) of right eye was 37.8 mmHg in dog I and 34.5 and 31.6 mmHg in the right and left...
متن کاملGlaucoma Surgery in Pregnancy: A Case Series and Literature Review
AbstractGlaucoma management in pregnant patients is a real challenge, especially when the glaucoma is not controlled with medications. We report the results of 6 incisional glaucoma surgeries for the management of medically uncontrolled glaucoma patients during pregnancy. This retrospective, case series was conducted on the 6 eyes of 3pregnant patients with uncontrolled glaucoma using maximum t...
متن کاملAnalytical and Numerical Investigation of Significant Parameters on Strength of Electromagnetically Assembled Products Joints
Electromagnetic forming is a high energy rate forming process. In this process, an electromagnetic Lorentz body force is used for deformation of products. In this article, Electromagnetic forming process was simulated for assembly of parts as an innovative method. In this research work, the effect of important parameters of process such as discharge energy, radius and width of rectangular groov...
متن کاملEYcacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucoma
Aims—To evaluate the eYcacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucomas. Methods—This retrospective study reviewed the final intraocular pressure, visual outcome, and incidence of complications in all patients with the Ahmed glaucoma valve implant performed at the Prince of Wales Hospital, Hong Kong, between June 1996 and November 1998. Results—A to...
متن کاملAnalytical and Numerical Investigation of Significant Parameters on Strength of Electromagnetically Assembled Products Joints
Electromagnetic forming is a high energy rate forming process. In this process, an electromagnetic Lorentz body force is used for deformation of products. In this article, Electromagnetic forming process was simulated for assembly of parts as an innovative method. In this research work, the effect of important parameters of process such as discharge energy, radius and width of rectangular groov...
متن کامل