Volatile Organic Compound (VOC) Removal by Vapor Permeation at Low VOC Concentrations: Laboratory Scale Results and Modeling for Scale Up
نویسندگان
چکیده
Petroleum transformation industries have applied membrane processes for solvent and hydrocarbon recovery as an economic alternative to reduce their emissions and reuse evaporated components. Separation of the volatile organic compounds (VOCs) (toluene-propylene-butadiene) from air was performed using a poly dimethyl siloxane (PDMS)/α-alumina membrane. The experimental set-up followed the constant pressure/variable flow set-up and was operated at ~21 °C. The membrane is held in a stainless steel module and has a separation area of 55 × 10-4 m². Feed stream was set to atmospheric pressure and permeate side to vacuum between 3 and 5 mbar. To determine the performance of the module, the removed fraction of VOC was analyzed by Gas Chromatography/Flame Ionization Detector (GC/FID). The separation of the binary, ternary and quaternary hydrocarbon mixtures from air was performed at different flow rates and more especially at low concentrations. The permeate flux, permeance, enrichment factor, separation efficiency and the recovery extent of the membrane were determined as a function of these operating conditions. The permeability coefficients and the permeate flux through the composite PDMS-alumina membrane follow the order given by the Hildebrand parameter: toluene > 1,3-butadiene > propylene. The simulated data for the binary VOC/air mixtures showed fairly good agreement with the experimental results in the case of 1,3-butadiene and propylene. The discrepancies observed for toluene permeation could be minimized by taking into account the effects of the porous support and an influence of the concentration polarization. Finally, the installation of a 0.02 m2 membrane module would reduce 95% of the VOC content introduced at real concentration conditions used in the oil industry.
منابع مشابه
Literature Review of Air Pollution Control Biofilters and Biotrickling Filters for Odor and Volatile Organic Compound Removal
A literature study was conducted to compare the feasibility of biofilters and biotrickling filters for the treatment of complex odorous waste air containing hydrogen sulfide (H2S), organic reduced sulfur compounds, and chlorinated and nonchlorinated volatile organic compounds (VOCs). About 40 pilot-plant studies and full-scale applications at wastewater treatment plants and other facilities wer...
متن کاملEffectiveness of Portable Room Air Cleaners for Control of Volatile Organic Compounds in Indoor Air
IAQ T1S3) Eleven commercially available portable room air cleaners have been tested on a mixture of 16 representative volatile organic compounds (VOC) in a full-scale stainless steel chamber and their initial VOC removal efficiencies have been evaluated. These products use different gas-phase contaminant removal technologies including adsorption, photocatalytic oxidation under UV irradiation (U...
متن کاملDiurnal and seasonal variability of gasoline-related volatile organic compound emissions in Riverside, California.
On- and off-road mobile sources are the dominant contributors to urban anthropogenic volatile organic compound (AVOC) emissions. Analyses of gasoline samples from California for both summer and winter indicate significant differences in liquid fuel and vapor chemical composition due to intentional seasonal adjustments. Ambient concentrations of 55 VOCs were measured via in situ gas chromatograp...
متن کاملPredicting the emission rate of volatile organic compounds from vinyl flooring.
A model for predicting the rate at which a volatile organic compound (VOC) is emitted from a diffusion-controlled material is validated for three contaminants (n-pentadecane, n-tetradecane, and phenol) found in vinyl flooring (VF). Model parameters are the initial VOC concentration in the material phase (C0), the material/air partition coefficient (K), and the material-phase diffusion coefficie...
متن کاملTreatment of Gaseous Volatile Organic Compounds in Activated Sludge System
An activated sludge aeration tank (W × L × H = 40 × 40 × 300 cm) with a set of 2 mm orifice air spargers was utilized to treat gas-borne volatile organic compounds (VOCs, toluene, p-xylene, and dichloromethane) in air streams. Effects of liquid depth, aeration intensity (G/A), overall mass transfer coefficient of oxygen in clean water (KLaO2), dimensionless Henry’s law coefficient of the tested...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 1 شماره
صفحات -
تاریخ انتشار 2011