Optimizing Pumping Systems to Minimize First or Life-cycle Cost
نویسندگان
چکیده
Numerical optimization methods offer a powerful new technology for pump users when combined with pumping system analysis software. Whether the design goal is to reduce first costs or life-cycle costs, this technology promises to significantly reduce pumping system costs and energy usage. Optimization methods work by automatically selecting pipe and pump sizes to minimize cost. Design engineers define the constraints for the system, such as flowrate, NPSH margin, or fluid velocity. The optimization software then finds the combination of pipe and pump sizes to minimize the cost while satisfying the constraints. 1 A new design concept is introduced called the optimal pumping system operating point (OPSOP). In simple terms, the OPSOP uses cost data to identify the optimum tradeoff in pipe, pump, and (optionally) energy costs for a system that may have one or more duty points. Using this information, a new and improved method of pump sizing is described. To establish benchmark comparisons for typical petrochemical pumping systems, these optimization methods were applied to four previously designed systems. With a modest amount of effort, first cost reductions were as much as 17 percent, and life-cycle cost reductions were as much as 72 percent (based on 10 years), with savings of over $100,000 in several cases.
منابع مشابه
Optimizing Pumping Systems to Minimize First or Life-cycle Cost
Numerical optimization methods offer a powerful new technology for pump users when combined with pumping system analysis software. Whether the design goal is to reduce first costs or life-cycle costs, this technology promises to significantly reduce pumping system costs and energy usage. Optimization methods work by automatically selecting pipe and pump sizes to minimize cost. Design engineers ...
متن کاملDetermination of Optimum Insulation Thickness for Building Walls in Iran Using Life Cycle Cost Analysis
Air-Conditioning (AC) systems are responsible for a considerable portion of the energy consumption in buildings located in high cooling load requiring regions of Iran. In addition, the heat flow through the buildingschr('39') external walls plays a major role in cooling load estimations for the countrychr('39')s hot regions. Therefore, application of insulation materials in external walls has g...
متن کاملOptimal System Design of In-Situ Bioremediation Using Parallel Recombinative Simulated Annealing
We present a simulation/optimization model combining optimization with BIOPLUME II simulation for optimizing in-situ bioremediation system design. In-situ bioremediation of contaminated groundwater has become widely accepted because of its cost-effective ability to achieve satisfactory cleanup. We use parallel recombinative simulated annealing to search for an optimal design and apply the BIOPL...
متن کاملEvaluating the role of company life cycle in optimizing the conservative model of ball and Shivakumar (2005)
The main purpose of this study is to evaluate the role of corporate life cycle in optimizing conservatism measurement based on the conditional conservatism model of Ball and Shivakumar (2005). The present study is an analytical-correlational study and the statistical population of the study consists of all companies listed on the Tehran Stock Exchange during the years 1387 to 1396 which include...
متن کاملSensorless frequency-converter-based methods for realizing life-cycle cost efficient pumping and fan systems
Frequency converters provide means for the energy efficient flow and pressure control in pumping and fan systems by varying the motor speed. Besides speed variation, a modern frequency converter can estimate the state and performance of system operation without additional measurement sensors. This ability provides several possibilities to optimize pumping or fan system operation and the resulti...
متن کامل