Corneal astigmatism after micro-incision cataract operation.

نویسندگان

  • Zlatko Musanovic
  • Vahid Jusufovic
  • Meliha Halibasica
  • Jasmin Zvornicanin
چکیده

GOALS To evaluate the effect of micro-incision (2.2 mm) and small-incision (3.0 mm) coaxial phaco-emulsification on surgically induced astigmatism (SIA). METHODS Cataract patients (n = 60, 60 eyes) were randomized into two groups: 30 eyes in the 2.2-mm incision group, 30 eyes in the 3,0-mm group. Phaco-emulsification was followed by intraocular lens implantation via the Monarch II injector with the C cartridge (Alcon Laboratories Inc., Fort Worth, TX, USA). Uncorrected distance visual acuity, corneal keratometry and corneal astigmatism and SIA were assessed 1, 7 and 30 days after cataract surgery. RESULTS At 1, 7 and 30 days postoperative, SIA of the 3.0-mm group was greater than SIA of the 2.2-mm (p < or = 0.05) only at first postoperative day, but SIA was similar between the 2.2-mm group and the 3,0-mm group at other follow-ups. Time wise, mean SIA at 30 days was greater than SIA at 90 days in the 3.0-mm group (p = 0.04), while SIA did less change with time for the 2.2-mm group. Postoperative uncorrected distance visual acuity tended to be better with the smaller incisions, but this trend did not reach statistical significance (p > or = 0.07) especially at letter follow-ups. CONCLUSION Incision size contributed to postoperative corneal astigmatism especially at earlier postoperative period. When incision size was reduced from 3.0 mm to 2.2 mm, SIA was reduced and refractive stabilization was faster. In longer period of time difference between 3,0 mm and 2,2 mm incision size groups decreases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Minimizing Surgically Induced Astigmatism at the Time of Cataract Surgery Using a Square Posterior Limbal Incision

Purpose. To compare the surgically induced astigmatism from clear corneal and square posterior limbal incisions at the time of cataract surgery. Methods. Surgically induced astigmatism was calculated for a set of eyes after cataract surgery using a temporal 2.2 mm square posterior limbal incision. Results were compared to similar available data from surgeons using clear corneal incisions of sim...

متن کامل

AcrySof IQ toric IOL implantation combined with limbal relaxing incision during cataract surgery for eyes with astigmatism >2.50 D.

PURPOSE To evaluate the effectiveness of toric intraocular lens (IOL) implantation combined with limbal relaxing incision (LRI) for patients with high-amplitude astigmatism. METHODS This single-center, prospective study evaluated 22 eyes of 19 patients with cataract and >2.50 diopters (D) astigmatism that underwent bimanual micro-phacoemulsification cataract surgery and toric IOL implantation...

متن کامل

The role of sideport incision in astigmatism change after cataract surgery

PURPOSE To study the changes in corneal astigmatism after cataract surgery when the sideport incision is performed at a predetermined location away from the tunnel incision. SETTING General Hospital of Piraeus "Tzaneio", Attiki, Greece. MATERIALS AND METHODS A total of 333 eyes with corneal astigmatism ≤1.5 diopters (D) underwent cataract surgery. A three-step superotemporal clear corneal i...

متن کامل

A comparative study of sclero-corneal and clear corneal tunnel incision in manual small-incision cataract surgery.

BACKGROUND Cataract surgery techniques have improved a lot over the years from couching to the latest micro-incision cataract surgery. OBJECTIVES To compare the temporal sclero-corneal and clear corneal tunnel incisions in patients undergoing manual small-incision cataract surgery (SICS) with respect to the surgically-induced astigmatism. MATERIALS AND METHODS The present study included 60 ...

متن کامل

Corneal astigmatism, high order aberrations, and optical quality after cataract surgery: microincision versus small incision.

PURPOSE To compare the astigmatism, high order aberrations, and optical quality of the cornea after microincision (approximately 1.7 mm) versus small incision approximately 3.2 mm) cataract surgery at Eye Center, Zhejiang University, Hangzhou, China. METHODS This prospective, randomized clinical study included microincision cataract surgery and small incision cataract surgery performed on 60 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medicinski arhiv

دوره 66 2  شماره 

صفحات  -

تاریخ انتشار 2012