In situ tensile testing of tin (Sn) whiskers in a focused ion beam (FIB)/scanning electron microscope (SEM)
نویسندگان
چکیده
Article history: Received 22 May 2017 Received in revised form 7 July 2017 Accepted 8 July 2017 Available online 19 July 2017 Tin and tin-alloyed electroplated films are known to be susceptible to whisker growth under a range of conditions,manyofwhich result in the generation of compressive stresses in thefilm. Compressive stress is considered to be one of the primary causes for whisker nucleation and growth. While extensive investigations have been performed on whisker growth, there have been few studies on the mechanical properties of tin whiskers themselves. We report on the tensile behavior of tin whiskers that were obtained by indentation and furnace aging of electroplated tinfilms on copper disks. Tensile tests of thewhiskerswere conducted in situ in a dual beam focused ion beam (FIB)-scanning electron microscope (SEM) system using a micro electro-mechanical systems (MEMS) based tensile testing stage. The strength of the whiskers was found to decrease with an increase in gage length and aged whiskers were found to be weaker than their indented counterparts. The observed gage length effect can be attributed to the probability of findingmore defects as the whisker length increases. The effect of processing on the observed strength variation was investigated by analyzing the oxygen content in the whiskers via energy dispersive spectroscopy and the microstructure through transmission electron microscopy (TEM). The deformationmechanisms of whiskers were also inferred using post-mortem TEM. It was observed that the whiskers grown by indentation were dislocation free both before and after deformation. In contrast, whiskers grown by aging showed notable dislocation content (arranged in low energy configurations) even before deformation. © 2017 Elsevier Ltd. All rights reserved.
منابع مشابه
Tensile Behavior of Single-Crystal Tin Whiskers
The growth of metallic (predominantly Sn) whiskers from pure metallic platings has been studied for over 50 years. While the phenomenon of Sn whiskering has been studied for decades, very little is known about the mechanical properties of these materials. This can be attributed to the difficulty in handling, gripping, and testing such fine-diameter and high-aspect-ratio whiskers. We report on t...
متن کاملInternal Microstructure Investigation of Tin Whisker Growth Using FIB Technology
The problem of tin (Sn) whiskers has been a significant reliability issue in electronics for the past several decades. Despite the large amount of research conducted on this issue, a solution for mitigating the growth of whiskers remains a challenge for the research community. Whiskers have unpredictable growth and morphology, and a study of a whisker’s internal structure may provide further in...
متن کاملCrystallographically-dependent ripple formation on Sn surface irradiated with focused ion beam
The metallographically polished polycrystalline Sn surface was sputtered by 30 kV focused Ga ions at room temperature. The experiment was carried out using various FIB incidence angles (08, 158, 308, and 458) over a wide range of doses (10– 10 ions/cm). The surface morphology was carefully characterized under the optical microscope, scanning electron microscope (SEM) and atomic force microscope...
متن کاملHow to study biological samples by FIB/SEM?
The focused ion beam (FIB)/scanning electron microscope (SEM) is a scanning microscope with an electron column and an ion column embedded in the same specimen chamber; both beams are aiming at the same point on the specimen surface. The FIB, generated by a Ga Liquid Metal Ion Source (LMIS), impacts the sample normal to the surface and can be focused to a spot as small as few nanometres. The FIB...
متن کاملPreparation of high-quality planar FeRh thin films for in situ TEM investigations
The preparation of a planar FeRh thin film using a focused ion beam (FIB) secondary electron microscope (SEM) for the purpose of in situ transmission electron microscopy (TEM) is presented. A custom SEM stub with 45° faces allows for the transfer and milling of the sample on a TEM heating chip, whilst Fresnel imaging within the TEM revealed the presence of the magnetic domain walls, confirming ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Microelectronics Reliability
دوره 79 شماره
صفحات -
تاریخ انتشار 2017