A 16-year study of the microgap between 272 human titanium implants and their abutments.
نویسندگان
چکیده
A microgap has been described at the level of the implant-abutment connection. This microgap can be colonized by bacteria, and this fact could have relevance on the remodeling of the peri-implant crestal bone and on the long-term health of the peri-implant tissues. The authors report on 272 implants with screw- or cement-retained abutments retrieved from humans for different causes during a 16-year period. In the implants with screw-retained abutments, a 60-microm microgap was present at the level of implant-abutment connection. In some areas the titanium had sheared off from the surface and from the internal threads. The contact between the threads of the implant and those of the abutment was limited to a few areas. Bacteria were often present in the microgaps between implant and abutment and in the internal portion of the implants. In implants with cement-retained abutments, a 40-microm microgap was found at the level of the implant-abutment connection. No mechanical damage was observed at the level of the implant or of the abutment. All the internal voids were always completely filled by the cement. No bacteria were observed in the internal portion of the implants or at the level of the microgap. The differences in the size of the microgap between the two groups were statistically significant (P < .05). In conclusion, in screw-retained abutments the microgap can be a critical factor for colonization of bacteria, whereas in cement-retained abutments all the internal spaces were filled by cement. In these retrieved implants, the size of the microgap was markedly variable and much larger than that observed in vitro.
منابع مشابه
Comparative Evaluation of Microgap at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study
Abstract Background and Aim : Microgap in the implant-abutment interface is one of the main challenges in the treatment of two-piece implants. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microgap at implant-abutment interface area under oblique cyclic loading in vitro. Methods and Materials In this in vitro study, 12 implant-abutment assemb...
متن کاملComparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study
Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...
متن کاملZirconia implant abutments: A review
PURPOSE: The aim of this study was to evaluate in vitro the microgap between different zirconia abutments and their titanium implants. MATERIALS AND METHODS: Four systems were evaluated: Procera zirconia (Nobel Biocare) (Nb), Cercon Balance Anterior (Dentsply Friadent) (Ba), ZirDesign (Astratech) (Zd), and Straumann Cares ceramic (Straumann) (Ca). Five assemblies were assessed for each system. ...
متن کاملمقایسه مقاومت شکست و نوع شکست اباتمنتهای زیرکونیایی مختلف در مقایسه با اباتمنتهای تیتانیومی
Background and Aims: One of the decisive factors on the final esthetic results of implant treatment is the abutment material. Ceramic abutments are nowadays very popular in this regard. The purpose of this study was to compare the fracture resistance of three zirconia abutments with titanium abutment. Materials and Methods: Four groups of abutments (five specimens in each) were prepared. The a...
متن کاملArtifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging
Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of oral implantology
دوره 31 6 شماره
صفحات -
تاریخ انتشار 2005