Interlocking contoured intramedullary nail fixation for selected diaphyseal fractures of the forearm in adults.
نویسندگان
چکیده
BACKGROUND Plate osteosynthesis is the most commonly used technique for the treatment of diaphyseal forearm fractures in adults. However, application of a plate can disrupt the periosteal blood supply and necessitates skin incisions that may be unsightly, and there is a risk of refracture if the implant is removed. The purpose of this study was to assess the early results of the use of a contoured interlocking intramedullary nail to stabilize displaced diaphyseal fractures of the forearm. METHODS Between January 2004 and July 2006, a total of thirty-eight interlocking intramedullary nails were inserted into the forearms of twenty-seven adults. Eighteen nails were used in the radius and twenty were used in the ulna to stabilize a diaphyseal fracture. The mean follow-up period was seventeen months. Functional outcomes were assessed with use of the Grace and Eversmann rating system, and patient-rated outcomes were assessed by completion of the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire. RESULTS The average time to fracture union was fourteen weeks. There was one nonunion of an open comminuted fracture of the middle third of the ulna. There were no deep infections or radioulnar synostoses. According to the Grace and Eversmann rating system, twenty-two patients (81%) had an excellent result; three (11%), a good result; and two (7%), an acceptable result. The DASH scores averaged 15 points (range, 5 to 61 points). CONCLUSIONS Our experience indicates that the advantages of an interlocking intramedullary nail system for the radius and ulna are that it is technically straightforward, it allows a high rate of osseous consolidation, and it requires less surgical exposure and operative time than does plate osteosynthesis. We suggest that the interlocking intramedullary nail system be considered as an alternative to plate osteosynthesis for selected diaphyseal fractures of the forearm in adults.
منابع مشابه
Operative Management of Fractures Shaft Tibia with Closed Intramedullary Interlocking Nail
Tibial diaphyseal fractures are one of the commonest long bone fractures encountered by most of the orthopaedic surgeons. There are many methods of treatment for tibial diaphyseal fractures. But now-a-days closed intramedullary interlocking nailing is emerging as treatment of choice for all closed tibial diaphyseal fractures, most of type Iand type II open fractures in adults. Closed IM IL nail...
متن کاملIntramedullary Interlocking Nail Fixation in Dogs and Cats: Biomechanics and Instrumentation*
of diaphyseal long bone fractures. Interlocking nails have transverse cannulations that accommodate transcortical screws, allowing surgeons to firmly fix the rod within the medullary canal, thereby effectively neutralizing bending, rotational, and axial forces that act on fractures. Interlocking nails have become increasingly To counter axial and rotational forces, intramedullary nails were dev...
متن کاملInternal fixation of shaft humerus fractures by dynamic compression plate or interlocking intramedullary nail: a prospective, randomised study
Compare the results of internal fixation of shaft of humerus fractures using dynamic compression plating (DCP) or antegrade interlocking intramedullary nail (IMN). Fifty patients with diaphyseal fracture of the shaft of the humerus and fulfilling the inclusion criterion were randomly assigned to one of the two groups. Twenty-five patients were managed with closed antegrade interlocking intramed...
متن کاملOutcome of Tibial Shaft Fractures Treated by Close Intramedullary Nail
Tibia is the most commonly fractured long bone in the body with an annual incidence of tibial shaft fractures 2 per 1000 individuals. The use of non-operative treatment of tibial fractures that are widely displaced or that are the result of high-energy forces is associated with a high prevalence of malunion, stiffness of the joint, and poor functional outcome. Closed Tibial diaphyseal fractures...
متن کاملOutcome of intramedullary interlocking SIGN nail in tibial diaphyseal fracture.
OBJECTIVE To determine the outcome of intramedullary interlocking surgical implant generation network (SIGN) nail in diaphyseal tibial fractures in terms of union and failure of implant (breakage of nail or interlocking screws). STUDY DESIGN Case series. PLACE AND DURATION OF STUDY Orthopaedics and Spinal Surgery, Ghurki Trust Teaching Hospital, Lahore Medical and Dental College, Lahore, fr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. American volume
دوره 90 9 شماره
صفحات -
تاریخ انتشار 2008