Development of "super rapid dynamic SPECT," and analysis of retention process of 99mTc-ECD in ischemic lesions: comparative study with 133Xe SPECT.

نویسندگان

  • Akio Komatani
  • Yukio Sugai
  • Takaaki Hosoya
چکیده

To analyze the retention process of technetium-99m ethyl cysteinate dimer (99mTc-ECD) in normal and ischemic lesions, we developed a super rapid dynamic SPECT system based on the CERASPECT (DSI, Inc., Waltham, MA, USA). The system made it possible to take a SPECT series every 2 seconds. Each SPECT series contains a maximum of 16 slices (6.6 mm slice interval) in a matrix size of 32 x 32. The sensitivity of this system is 175 kcps/MBq/ml/cm slice thickness, and resolution is 12 mm FWHM at the center of a 20 cm(phi) water phantom. Using the super rapid SPECT system, the kinetic behavior of the 99mTc-ECD during retention in normal and ischemic lesions was analyzed. Twenty patients with ischemic lesions that were clearly demonstrated by 133Xe-rCBF (regional cerebral blood flow) SPECT but unclear on static 99mTc-ECD SPECT were examined. For the dynamic SPECT, 700 MBq of 99mTc-ECD was injected intravenously, and dynamic SPECT data were acquired every 2 seconds during a 90-second period. The serial dynamic SPECT and time-activity curves at some lesions with reduced rCBF and at the contralateral normal brain were analyzed. These dynamic SPECT data were compared with conventional static 99mTc-ECD SPECT and quantitative 133Xe-rCBF SPECT. All of mildly or moderately reduced rCBF lesions on the 133Xe-rCBF SPECT were recognized as low activity regions only at the early phase (during about 2-20 sec or less), with the lesions then gradually vanishing. These lesions were not recognized on the conventional static SPECT taken after the dynamic study. The time-activity curve at the reduced rCBF lesion was lower than that of contralateral normal brain at the early phase, and overtook the activity in the normal region with a gradual increase. The early phase images of 99mTc-ECD SPECT within 20 seconds by the super rapid dynamic SPECT were very useful to the same extent as the 133Xe-rCBF SPECT for detecting mild or moderate ischemic lesions. This study suggests that esterase activity, participating in the ECD retention mechanism, may be tolerable to mild or moderate ischemia. This tolerance may be the main cause of the nonlinear relationship between ECD accumulation and cerebral blood flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic and static 99mTc-ECD SPECT imaging of subacute cerebral infarction: comparison with 133Xe SPECT.

UNLABELLED 99mTc-ethylcysteinate dimer (99mTc-ECD) SPECT imaging reportedly fails to show reflow hyperemia in patients with subacute stroke. This study attempts to determine the clinical usefulness of dynamic 99mTc-ECD SPECT in evaluating regional blood flow in subacute cerebral infarction and the kinetic behavior of 99mTc-ECD in infarct areas. METHODS 133Xe and consecutive dynamic and static...

متن کامل

Brain single-photon emission CT studies using 99mTc-HMPAO and 99mTc-ECD early after recanalization by local intraarterial thrombolysis in patients with acute embolic middle cerebral artery occlusion.

BACKGROUND AND PURPOSE The brain distribution of 9mTc-hexamethylpropyleneamine oxime (HMPAO) correlates with regional brain perfusion, whereas 99mTc-ethyl cysteinate dimer (ECD) reflects not only perfusion but also the metabolic status of brain tissue. We compared 99mTc-ECD single-photon emission CT (SPECT) with 99mTc-HMPAO SPECT early after recanalization by local intraarterial thrombolysis (L...

متن کامل

Gas Dynamic SPECT and Thin-Section CT in Patients wih Pulmonary Emphysema

[Purpose] We assessed 133Xe gas dynamic single photon emission computed tomography (SPECT) by comparing washout axial images with thin-section CT (TSCT) in patients with pulmonary emphysema. [Methods] Twenty-three patients were studied. All patients were diagnosed as having pulmonary emphysema on the basis of TSCT. We compared TSCT of upper, middle and lower lung fields with 133Xe gas dynamic S...

متن کامل

The value of the Gated 99mTc-MIBI SPECT in differentiation of fixed myocardial lesions [Persian]

Fixed myocardial defects in both stress and rest images, could be artifactual as a result of soft tissue attenuation. To increase specificity and identify the false positive results, we used gated technique to evaluate the wall motion and wall thickening as an index to differentiate real ischemic lesions from artifactual defects. 93 patients were studied. In 46 patients (48.8%) fixed perf...

متن کامل

Utility of 99mTc-Sestamibi SPECT/CT in the Early Localization of Metastatic Parathyroid Carcinoma

Parathyroid carcinoma is very rare, with only a few documented cases. Hence, metastatic lesions are infrequently documented on scintigraphic imaging. We present a case of a 63-year-old female presenting with elevated serum levels of ionized calcium and parathyroid hormone (PTH) who was referred to our department for a parathyroid scan with SPECT/ CT. Parathyroid scintigraphy showed a focus of i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 18 6  شماره 

صفحات  -

تاریخ انتشار 2004