An optimized SPE-LC-MS/MS method for antibiotics residue analysis in ground, surface and treated water samples by response surface methodology- central composite design

نویسندگان

  • Roya Mirzaei
  • Masoud Yunesian
  • Simin Nasseri
  • Mitra Gholami
  • Esfandiyar Jalilzadeh
  • Shahram Shoeibi
  • Hooshang Shafieyan Bidshahi
  • Alireza Mesdaghinia
چکیده

BACKGROUND Antibiotic residues are being constantly identified in environmental waters at low concentration. Growing concern has been expressed over the adverse environmental and human health effects even at low concentration. Hence, it is crucial to develop a multi-residues analytical method for antibiotics to generate a considerable dataset which are necessary in the assessment of aquatic toxicity of environmental waters for aquatic organisms and human health. This work aimed to develop a reliable and sensitive multi-residue method based on high performance liquid chromatography coupled with quadrupole-linear ion trap tandem mass spectrometry (HPLC-MS-MS). The method was optimized and validated for simultaneous determination of four classes of antibiotics including, β-lactam, macrolide, fluoroquinolone and nitro-imidazole in treated, ground and surface water matrices. METHODS In order to optimize the solid phase extraction process, main parameters influencing the extraction process including, pH, the volume of elution solvent and the amount of Na4EDTA were evaluated. The optimization of extraction process was carried out by response surface methodology using central composite design. Analysis of variance was performed for nine target antibiotics using response surface methodology. RESULTS The extraction recoveries were found to be sensitive to the independent variables of pH, the volume of elution solvent and the amount of Na4EDTA. The extraction process was pH-dependent and pH was a significant model term in the extraction process of all target antibiotics. Method validation was performed in optimum operation conditions in which the recoveries were obtained in the range of 50-117% for seven antibiotics in spiked treated and ground water samples and for six antibiotics in spiked river water samples. Method validation parameters in terms of method detection limit were obtained in the range of 1-10 ng/L in treated water, 0.8-10 ng/L in the ground water and 0.8-25 ng/L in river water, linearity varied from 0.95 to 0.99 and repeatability in term of relative standard deviation values was achieved less than 10% with the exception for metronidazole and ceftriaxone. The developed method was applied to the analysis of target antibiotics in treated, ground and surface water samples. CONCLUSIONS Target antibiotics were analyzed in different water matrices including treated, ground and river water. Seven out of nine antibiotics were detected in Kan River and Firozabad Ditch water samples, although none of them were detected in treated water and ground water samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Screening and Optimization of Microextraction of Pb(II) by Inductively Coupled Plasma-Atomic Emission Using Response Surface Methodology

Dispersive liquid–liquid microextraction (DLLME) combined with inductively coupled plasma-atomic emission spectrometry (ICP-AES) was applied for the determination of lead in different environmental water samples. Ammonium pyrrolidine dithiocarbamate (APDC), chloroform and ethanol were used as chelating agent, extraction solvent and disperser solvent, respectively. The effective parameters, such...

متن کامل

A New Dispersive Liquid-Liquid Microextraction Method Followed by Direct GF-AAS Determination Optimized with Experimental Design and Response Surface Methodology for Determination of Ag(I) in Water Samples

In this research, a rapid, reliable and selective dispersive liquid-liquid microextraction (DLLME) followed by direct injection of microdroplet to graphite furnace atomic absorption spectrometry (GF-AAS) method for the determination of ultra-trace amounts of Ag(I) was developed. Effect of the important experimental parameters on the extraction efficiency of Ag(I) was investigated using response...

متن کامل

Simultaneous determination of selected endocrine disrupters (pesticides, phenols and phthalates) in water by in-field solid-phase extraction (SPE) using the prototype PROFEXS followed by on-line SPE (PROSPEKT) and analysis by liquid chromatography-atmospheric pressure chemical ionisation-mass spectrometry.

In this study, a new procedure, based on on-line solid-phase extraction (SPE) and analysis by liquid-chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS), has been developed for the simultaneous, multianalyte determination of 21 selected pesticides, phenols and phthalates in water. SPE was carried out on polymeric PLRP-s cartridges by percolating 20 mL-samples....

متن کامل

A Developed Electromembrane Technique Based on Flat Electrospun Membrane Coupled with Gas-chromatography for the Determination of Phthalates in Different Water Samples

In this work, we successfully developed electromembrane extraction via preparation of an electrospun flat membrane based on device. The polyurethane-membrane was prepared by electrospinning method and used in EME. Affecting parameters on membrane preparation were optimized by Taguchi design. The developed method was used for extraction of phthalates as typical molecules and the proposed method ...

متن کامل

Thermodynamic Analysis and Statistical Investigation of Effective Parameters for Gas Turbine Cycle using the Response Surface Methodology

In this paper, the statistical analyses are presented to study the thermal efficiency and power output of gas turbine (GT) power plants. For analyzing gas turbine operation and performance, a novel approach is developed utilizing the response surface methodology (RSM) which is based on the central composite design (CCD) method. An attempt is made to study the effect of some operational factors ...