Defining the mid-diastolic imaging period for cardiac CT – lessons from tissue Doppler echocardiography
نویسندگان
چکیده
BACKGROUND Aggressive dose reduction strategies for cardiac CT require the prospective selection of limited cardiac phases. At lower heart rates, the period of mid-diastole is typically selected for image acquisition. We aimed to identify the effect of heart rate on the optimal CT acquisition phase within the period of mid-diastole. METHODS We utilized high temporal resolution tissue Doppler to precisely measure coronary motion within diastole. Tissue-Doppler waveforms of the myocardium corresponding to the location of the circumflex artery (100 patients) and mid-right coronary arteries (50 patients) and the duration and timing of coronary motion were measured. Using regression analysis an equation was derived for the timing of the period of minimal coronary motion within the RR interval. In a validation set of 50 clinical cardiac CT examinations, we assessed coronary motion artifact and the effect of using a mid-diastolic imaging target that was adjusted according to heart rate vs a fixed 75% phase target. RESULTS Tissue Doppler analysis shows the period of minimal cardiac motion suitable for CT imaging decreases almost linearly as the RR interval decreases, becoming extinguished at an average heart rate of 91 bpm for the circumflex (LCX) and 78 bpm for the right coronary artery (RCA). The optimal imaging phase has a strong linear relationship with RR duration (R2 = 0.92 LCX, 0.89 RCA). The optimal phase predicted by regression analysis of the tissue-Doppler waveforms increases from 74% at a heart rate of 55 bpm to 77% at 75 bpm. In the clinical CT validation set, the optimal CT acquisition phase similarly occurred later with increasing heart rate. When the selected cardiac phase was adjusted according to heart rate the result was closer to the optimal phase than using a fixed 75% phase. While this effect was statistically significant (p < 0.01 RCA/LCx), the mean effect of heart-rate adjustment was minor relative to typical beat-to-beat variability and available precision of clinical phase selection. CONCLUSION High temporal resolution imaging of coronary motion can be used to predict the optimal acquisition phase in cardiac CT. The optimal phase for cardiac CT imaging within mid-diastole increases with increasing heart rate although the magnitude of change is small.
منابع مشابه
Evaluation of tissue doppler echocardiography and T2* magnetic resonance imaging in iron load of patients with thalassemia major
Background: Iron-mediated cardiomyopathy is the main complication of thalassemia major (TM) patients. Therefore, there is an important clinical need in the early diagnosis and risk stratification of patients. The aim of this study was to evaluate the efficacy of tissue doppler imaging (TDI) to study cardiac iron overload in patients with TM using T2* magnetic resonance (MR) as the gold-standard...
متن کاملNon-invasive estimation of cardiac wall stress by using tissue doppler-echocardiography ultrasound images: People with coronary artery stenosis
In this study, a method for non-invasive estimation of stress on the heart wall in the diastole phase is presented using ultrasound echocardiography and tissue Doppler imaging. The aim of this study was to evaluate the stress on the heart wall as a pre-diagnosis to identify people with coronary artery stenosis. 29 patients with stenosis of more than 70%, 30 patients with stenosis of 50 to 7...
متن کاملTissue Doppler Imaging versus Conventional Echocardiography in Evaluation of Cardiac Functions in Diabetes Mellitus
Background: Conventional echocardiography and tissue Doppler imaging have been highlighted to diagnose diastolic and systolic heart dysfunction. We aimed to compare tissue Doppler imaging with conventional echocardiography to diagnose heart dysfunctions in diabetes mellitus type 1 (DMT1) patients. <s...
متن کاملEchocardiographic Assessment of Left Ventricle Torsion by Tissue Doppler and Velocity Vector Imaging
Introduction Left ventricular (LV) twist is believed to store potential energy and plays an important role in generating diastolic suction. Recent advances in echocardiography techniques have allowed quantification of LV twist. The aim of the present study was to compare LV twist and torsion in healthy human subjects determined by velocity vector imaging (VVI) and tissue Doppler imaging (TDI) a...
متن کاملتوانایی اکوکاردیوگرافی داپلر در تخمین فشار پرشدگی بطن چپ در تنگی دریچه میترال
Background: Estimation of Left Ventricular End Diastolic Pressure (LVEDP) among patients with Mitral Stenosis (MS) helps to diagnose diastolic dysfunction and to explain their symptoms. However, Conventional Doppler measurements have limitation in predicting of LVEDP. This study sought to establish whether the correlation between measurements derived from Tissue Doppler echocardiography and LVE...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 13 شماره
صفحات -
تاریخ انتشار 2013