Analytical validation of the new plasma calibrated Accu-Chek Test Strips (Roche Diagnostics).

نویسندگان

  • Cécile Meex
  • José Poncin
  • Jean-Paul Chapelle
  • Etienne Cavalier
چکیده

BACKGROUND The Accu-Chek Inform glucose monitor is a point-of-care system for testing blood glucose. New test strips, calibrated to deliver glucose plasma-like values, were launched on the market in May 2005. The aim of our study was to perform analytical validation of these new strips. METHODS We compared the new plasma strips with whole blood strips; results for the plasma strips with plasma values obtained using a clinical analyzer and with whole blood values given by the glucose electrode of a blood gas analyzer; and the influence of the type of blood (capillary or venous) on the results obtained by the glucose monitor with the plasma calibrated strips. RESULTS Plasma strips give on average 7% higher results than the previous whole blood strips. However, the results given by the plasma strips on capillary whole blood, even if well correlated, are not completely comparable with those given by an analyzer for venous plasma. Nevertheless, these plasma strips and the glucose electrode of a blood gas analyzer give comparable results. CONCLUSIONS Accu-Chek Inform plasma strips are a good method for monitoring of blood glucose values in patients with diabetes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

"No coding" of glucose test strips: a roche perspective.

INTRODUCTION Glucose test strips vary slightly from batch to batch. These variations are accounted for by a batch-specific "code": a set of parameters defining the relationship between the signal change induced on the glucose test strip and the blood glucose concentration. METHODS We assessed the impact on accuracy of miscoding the ACCU-CHEK Aviva system across a wide range of glucose test st...

متن کامل

Assessment of three frequently used blood glucose monitoring devices in clinical routine.

BACKGROUND Self-monitoring of blood glucose plays an important role in the management of diabetes and has been shown to improve metabolic control. The use of blood glucose meters in clinical practice requires sufficient reliability to allow adequate treatment. Direct comparison of different blood glucose meters in clinical practice, independent of the manufactures is scarce. We, therefore, aime...

متن کامل

Self-monitoring of blood glucose levels requires intensive training for use of meters to obtain reliable and clinically relevant measurements.

BACKGROUND Anecdotal reports from pediatric sites have indicated that some blood glucose meters may display wrong and misleading numbers rather than error indications, when operated in deviation from the instructions for use (IFU), eg by manipulating the strip during the count-down phase. METHODS This study was performed with 60 patients with diabetes (32 female, 28 male, 21 type 1, 39 type 2...

متن کامل

Dynamic electrochemistry corrects for hematocrit interference on blood glucose determinations with patient self-measurement devices.

BACKGROUND It has been demonstrated that dynamic electrochemistry can be used to correct blood glucose measurement results for potentially interfering conditions, such as humidity, hematocrit (HCT) variations, and ascorbic acid. The purpose of this laboratory investigation was to assess the potential influence of hematocrit variations on a variety of blood glucose meters applying different meas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry and laboratory medicine

دوره 44 11  شماره 

صفحات  -

تاریخ انتشار 2006