Diagnosis of unruptured intracranial aneurysms: 3T MR angiography versus 64-channel multi-detector row CT angiography.

نویسندگان

  • Yoshiyasu Hiratsuka
  • Hitoshi Miki
  • Ikuko Kiriyama
  • Keiichi Kikuchi
  • Shizue Takahashi
  • Ichiro Matsubara
  • Kazuhiko Sadamoto
  • Teruhito Mochizuki
چکیده

BACKGROUND AND PURPOSE We compared 3-dimensional time-of-flight magnetic resonance angiography (3D TOF MRA) using a 3-tesla (T) MR unit with 64-channel multi-detector row computed tomographic angiography (64-MDCTA) for detection and characterization of angiographically proven unruptured intracranial aneurysms. METHODS Thirty-eight patients with 47 aneurysms and 8 patients without aneurysms underwent 3T, 3D TOF MRA; 64-MDCTA; and intra-arterial angiography. As a first study, 3 radiologists blinded to pertinent clinical information independently reviewed MRA and CTA images. We evaluated diagnostic accuracy using an alternative free-response receiver operating characteristic (AFROC) analysis and evaluated the sensitivity and specificity of each technique. Next, 2 radiologists used volume-rendering images generated from MRA or CTA data to evaluate the morphology of the 47 aneurysms detected, and MRA and CTA results were compared. Three-dimensional digital angiography (DA) images were used as the standard of reference. RESULTS On the AFROC analysis, the value of the mean area under the AFROC curve (A(1)) was 0.91 for both modalities. Mean sensitivity of 89% and specificity of 76% for MRA were not significantly different from sensitivity of 87% and specificity of 79% for CTA. Therefore, when used to evaluate aneurysmal morphology, both modalities appear satisfactory for determining these vascular anomalies. CONCLUSION Three-tesla, 3D TOF MRA and 64-MDCTA are excellent modalities with high diagnostic accuracy for evaluating unruptured intracranial aneurysms and no significant difference between them in diagnostic performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intravenous 3D digital subtraction angiography in the diagnosis of unruptured intracranial aneurysms.

Recent progress in digital subtraction angiography (DSA) devices makes it possible to perform rotational angiography with high resolution and high sensitivity. We tried intravenous (IV) 3D DSA in patients who had undergone MR angiography (MRA) suggestive of unruptured intracranial aneurysms. IV 3D DSA can be used as an alternative method for imaging unruptured intracranial aneurysms suggested o...

متن کامل

De Novo aneurysms in long–term follow-up CT-angiography of patients with clipped intracranial aneurysms

Background: This study was conducted to evaluate the de Novo aneurysm formation in the long-term follow-up of patients with clipped intracranial aneurysms. Methods: A total of 459 patients underwent the clipping of ruptured cerebral aneurysms in our institution during 1997 -2008. Of them, 119 patients were available in good condition and agreed to undergo 64 detector row computed tomography (CT...

متن کامل

A pitfall in detection of intracranial unruptured aneurysms on three-dimensional phase-contrast MR angiography.

We report three cases of intracranial unruptured aneurysm evaluated with MR angiography using both three-dimensional time-of-flight and three-dimensional phase-contrast techniques. It has been said that the phase-contrast technique has advantages over the time-of-flight technique in the detection of intracranial aneurysms. However, in our three cases, three-dimensional time-of-flight MR angiogr...

متن کامل

Sixty-four-row multislice computed tomographic angiography in the diagnosis and characterization of intracranial aneurysms: comparison with 3D rotational angiography.

BACKGROUND Sixty-four-row multislice computed tomographic angiography (CTA) has great potential for use in vascular studies. The aim of our study was to compare 64-slice CTA with three-dimensional rotational angiography (3DRA) in the detection and characterization of intracranial aneurysms with special attention to smaller (<3-mm) aneurysms. METHODS In a prospective study, a total of 133 pati...

متن کامل

Noninvasive detection of a ruptured aneurysm at a basilar artery fenestration with submillimeter multisection CT angiography.

The criterion standard for the detection of intracranial aneurysms is digital subtraction angiography. MR imaging and CT provide good accuracy in the evaluation of brain arteries and aneurysms. We herein report a case of a ruptured aneurysm at a basilar artery fenestration. The diagnosis was assessed with 16-row multisection CT angiography and was confirmed by using digital subtraction angiogra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine

دوره 7 4  شماره 

صفحات  -

تاریخ انتشار 2008