Corneal changes and wavefront analysis after orthokeratology fitting test.

نویسندگان

  • Iane Gonçalves Stillitano
  • Maria Regina Chalita
  • Paulo Schor
  • Eduardo Maidana
  • Marcelo Mastromonico Lui
  • Cesar Lipener
  • Ana Luisa Hofling-Lima
چکیده

PURPOSE To evaluate corneal changes and ocular aberrations during an orthokeratology test. DESIGN A prospective, nonrandomized cohort study. METHODS Fourteen myopic patients (26 eyes) underwent an orthokeratology fitting test with the BE contact lens (Ultravision Pty, Ltd, Brisbane, Australia). Best spectacle-corrected visual acuity (BSCVA), uncorrected (Ultravision Pty, Ltd, Brisbane, Australia) visual acuity (UCVA), subjective cycloplegic refraction, biomicroscopy, corneal topography, optical pachymetry, and aberrometry were performed at baseline and one and eight nights orthokeratology. The short-term effect of orthokeratology using corneal topography, tomography, and ocular aberrations was evaluated. RESULTS The mean spherical equivalent changed from -2.24 +/- 0.98 diopters (D) at baseline to 0.15 +/- 0.76 D after the eight nights of lens wear (P = .001). All patients had an UCVA of 20/30, 69.2% with 20/20. Changes in central corneal pachymetry were not observed. There was a statistically significant increase in the temporal corneal thickness from night one, without any difference between nights one and eight (P > .001). A significant increase of higher-order root mean square values was observed from baseline (0.42 +/- 0.16 mum), night one (0.81 +/- 0.24 mum), and night eight (1.04 +/- 0.24 mum). Increases in coma (Z7+Z8) and spherical aberration (Z12) were observed. Positive horizontal (Z8) coma increased in right eyes, and negative horizontal (Z8) coma increased in left eyes (P < .001). CONCLUSIONS Myopia reduction resulting from rapid central corneal flattening and improvement of UCVA occurred after orthokeratology. Higher-order aberrations (HOAs), particularly spherical aberration and coma, increased significantly during the orthokeratology test. An increase of temporal pachymetry and differences in coma direction induced between the eyes may be related to the subclinical lens decentration temporally.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recovery of corneal irregular astigmatism, ocular higher-order aberrations, and contrast sensitivity after discontinuation of overnight orthokeratology.

AIMS To examine prospectively the recovery of various parameters after discontinuation of overnight orthokeratology. METHODS Seventeen subjects undergoing orthokeratology for 12 months were examined. Refraction, corneal topography, wavefront aberrometry, a visual acuity test and a contrast sensitivity test were performed at baseline, 12 months after commencement of the procedure, and 1 week a...

متن کامل

The relationship between corneal biomechanics and anterior segment parameters in the early stage of orthokeratology

To investigate the relationship between corneal biomechanics and anterior segment parameters in the early stage of overnight orthokeratology.Twenty-three eyes from 23 subjects were involved in the study. Corneal biomechanics, including corneal hysteresis (CH) and corneal resistance factor (CRF), and parameters of the anterior segment, including corneal curvature, central corneal thickness (CCT)...

متن کامل

Vertical and horizontal thickness profiles of the corneal epithelium and Bowman's layer after orthokeratology.

PURPOSE To investigate thickness profile changes of the corneal epithelium and Bowman's layer at the vertical and horizontal meridians with overnight myopia orthokeratology (OK) lenses. METHODS Twenty subjects (age range: 19-33 years) wore reverse-geometry rigid gas-permeable OK lenses in both eyes for 30 days. Before lens wear and after 1, 7, and 30 days of overnight lens wear, evaluation of...

متن کامل

Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software

Purpose. To evaluate the repeatability and reproducibility of quantitative analysis of the morphological corneal changes after orthokeratology treatment using "Image-Pro Plus 6.0" software (IPP). Methods. Three sets of measurements were obtained: two sets by examiner 1 with 5 days apart and one set by examiner 2 on the same day. Parameters of the eccentric distance, eccentric angle, area, and r...

متن کامل

Influence of Overnight Orthokeratology on Corneal Surface Shape and Optical Quality

Purpose To investigate the changes of corneal surface shape and optical quality during orthokeratology. Methods 49 eyes of 26 patients (10.63 ± 2.02 years old) who underwent overnight orthokeratology for myopia were prospectively examined. The corneal surface shape parameters, including surface regularity index (SRI) and surface asymmetry index (SAI), were attained with an OPD-III SCAN. The h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of ophthalmology

دوره 144 3  شماره 

صفحات  -

تاریخ انتشار 2007