Assay Method Development and Validation for Simultaneous Quantitative Estimation of Diloxanide Furoate and Tinidazole in Tablets by Rp-hplc
نویسندگان
چکیده
Objective: To develop an accurate, precise and linear Reverse-Phase High-Performance Liquid Chromatographic (RP-HPLC) method for simultaneous quantitative estimation of Diloxanide furoate and Tinidazole in tablets and validate as per ICH guidelines. Methods: The optimized method uses a reverse phase column, Waters Symmetry C18 (250 X 4.6 mm; 5μ), a mobile phase of triethylammonium phosphate buffer (pH 2.3):acetonitrile in the proportion of 40:60 v/v, flow rate of 1.0 ml/min and a detection wavelength of 270 nm using a UV detector. Results: The developed method resulted in Diloxanide furoate eluting at 4.07 min and Tinidazole at 2.52 min. Diloxanide furoate exhibited linearity in the range 31.25-93.75μg/ml, while Tinidazole exhibited linearity in the range 37.5-112.5μg/ml. The precision is exemplified by relative standard deviations of 0.90% for Diloxanide furoate and 0.68% for Tinidazole. Percentage Mean recoveries were found to be in the range of 98-102, during accuracy studies. The limit of detection (LOD) for Diloxanide furoate and Tinidazole were found to be 68.53μg/ml and 97.87μg/ml respectively, while the limit of quantitation (LOQ) for Diloxanide furoate and Tinidazole were found to be 207.677μg/ml and 296.6μg/ml respectively. Conclusion: A simple, accurate, precise, linear and rapid RP-HPLC method was developed for simultaneous quantitative estimation of Diloxanide furoate and Tinidazole in tablets and validated as per ICH guidelines. Hence, it can be used for the routine analysis of Diloxanide furoate and Tinidazole in tablets in various pharmaceutical industries.
منابع مشابه
Analytical method development and validation of diloxanide furoate and ornidazole in its combined pharmaceutical dosage form
A simple, rapid, economical, precise and accurate Stability indicating RP-HPLC method for simultaneous estimation of Diloxanide Furoate and Ornidazole in Their Combined Dosage Form has been developed. The separation was achieved by LC20 AT C18 (250mm x 4.6 mm x 2.6 μm) column and Buffer (pH 4.5): Acetonitrile (40:60) as mobile phase, at a flow rate of 1 ml/min. Detection was carried out at 277 ...
متن کاملRPLC Determination of Tinidazole and Diloxanide Furoate in Tablets
A simple reverse phase liquid chromatographic method has been developed and subsequently validated for simultaneous determination of tinidazole and diloxanide furoate. The separation was carried out using a mobile phase consisting of acetonitrile, methanol and 0.2 M potassium dihydrogen phosphate (pH 5) in the ratio 2:3:2.The column used was SS Wakosil-II C-18 with a flow rate of 1 ml/min and U...
متن کاملSimultaneous RP-HPLC and UV Spectroscopic Method Development and Validation for Estimation of Ibandronate Sodium in Bulk and Pharmaceutical Dosage Form
The present study describes a simple, accurate, precise and cost effective UV-Vis Spectroscopic and RP-HPLC method for the estimation of Ibandronate sodium (IBN). The determination of Ibandronate sodium (IBN) was performed by both UV and RP-HPLC method using 215 nm as the determination wavelength. The drug was dissolved in NaOH solution (0.1N NaOH) for estimation in UV and in distilled water fo...
متن کاملSimultaneous estimation of amlodipine besylate and nebivolol hydrochloride in pharmaceutical tablets formulation by RP-HPLC using PDA detector
Background: The present work was undertaken with the aim to develop and validate a rapid and consistent RP-HPLC method in which the peaks will be appear with short period of time as per ICH Guidelines. Materials and Methods: The separation was achieved on a a stainless steel analytical column, Eclipse XDB plus C18 column (4.6 X 150 mm; 5 μm) in an isocratic mode. The mobile phase w...
متن کاملA New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms
A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms. Abstract The objective of the work is to develop and validate a new, simple, highly sensitive, stability indicating RP-HPLC method for simultaneous estimation of Dolutegravir and Rilpivirine in bulk and its dosage f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2015