Allergy to orthopedic metal implants - a prospective study.
نویسندگان
چکیده
OBJECTIVES Evaluation of the allergenic properties of the metal knee or hip joint implants 24 months post surgery and assessment of the relation between allergy to metals and metal implants failure. MATERIALS AND METHODS The study was conducted in two stages. Stage I (pre-implantation) - 60 patients scheduled for arthroplasty surgery. Personal interview, dermatological examination and patch testing with 0.5% potassium dichromate, 1.0% cobalt chloride, 5.0% nickel sulfate, 2.0% copper sulfate, 2.0% palladium chloride, 100% aluminum, 1% vanadium chloride, 5% vanadium, 10% titanium oxide, 5% molybdenum and 1% ammonium molybdate tetrahydrate were performed. Stage II (post-surgery) - 48 subjects participated in the same procedures as those conducted in Stage I. RESULTS Stage I - symptoms of "metal dermatitis" were found in 21.7% of the subjects: 27.9% of the females, 5.9% of the males. Positive patch test results were found in 21.7% of the participants, namely to: nickel (20.0%); palladium (13.3%); cobalt (10.0%); and chromium (5.9%). The allergy to metals was confirmed by patch testing in 84.6% of the subjects with a history of metal dermatitis. Stage II - 10.4% of the participants complained about implant intolerance, 4.2% of the examined persons reported skin lesions. Contact allergy to metals was found in 25.0% of the patients: nickel 20.8%, palladium 10.4%, cobalt 16.7%, chromium 8.3%, vanadium 2.1% Positive post-surgery patch tests results were observed in 10.4% of the patients. The statistical analysis of the pre- and post-surgery patch tests results showed that chromium and cobalt can be allergenic in implants. CONCLUSIONS Metal orthopedic implants may be the primary cause of allergies. that may lead to implant failure. Patch tests screening should be obligatory prior to providing implants to patients reporting symptoms of metal dermatitis. People with confirmed allergies to metals should be provided with implants free from allergenic metals.
منابع مشابه
Allergic reaction to vanadium causes a diffuse eczematous eruption and titanium alloy orthopedic implant failure.
Allergy as a cause of adverse outcomes in patients with implanted orthopedic hardware is controversial. Allergy to titanium-based implants has not been well researched, as titanium is traditionally thought to be inert. We highlight the case of a patient who developed systemic dermatitis and implant failure after surgical placement of a titanium alloy (Ti6Al4V) plate in the left foot. The hardwa...
متن کاملHypersensitivity to Orthopedic Implants: A Review of the Literature
Awareness of rare etiologies for implant failure is becoming increasingly important. In addition to the overall increase in joint arthroplasties, revision surgeries are projected to increase dramatically in the coming years, with volume increasing up to seven-fold between 2005 and 2030. The literature regarding the relationship between metal allergy and implant failure is controversial. It has ...
متن کاملProspective analysis of human leukocyte functional tests reveals metal sensitivity in patients with hip implant
BACKGROUND The aim of the study was to examine the reactivity of peripheral human leukocytes to various metal ions prior and following hip replacement in order to investigate implant-induced metal sensitivity. METHODS Three patient groups were set up: (1) individuals without implants and no history of metal allergy (7 cases), (2) individuals without implants and known history of metal allergy...
متن کاملMetal Hypersensitivity Reactions to Orthopedic Implants
Total hip and knee replacement surgery using metal alloy devices is common. Type IV allergic reactions to these implants occur, though infrequently. While uncommon, peri-implant metal allergic reactions may cause significant morbidity for the affected individual-including aseptic loosening, pseudotumor formation and frank device failure. It is challenging to predict who will have these reaction...
متن کاملSystemic contact dermatitis to a surgical implant presenting as red decorative tattoo reaction
SCD: systemic contact dermatitis INTRODUCTION Up to 5% of orthopedic implant patients suffer metal-related cutaneous complications caused by delayed-type hypersensitivity reactions, most commonly to nickel, cobalt, and chromium. Both generalized and remote site dermatitis to orthopedic implants are uncommon. Traditional and decorative tattoos have been given for thousands of years around the wo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of occupational medicine and environmental health
دوره 25 4 شماره
صفحات -
تاریخ انتشار 2012