paper_new submitted to World Scientific 4/6/00 : 22:47 1/1 LIMITATIONS ON THE RESOLUTION OF YAG:CE BEAM PROFILE MONITOR FOR HIGH BRIGHTNESS ELECTRON BEAM

نویسندگان

  • A. MUROKH
  • J. ROSENZWEIG
  • V. YAKIMENKO
  • E. JOHNSON
  • X. J. WANG
چکیده

The performance of single crystal YAG:Ce (Y3Al5O12 ) beam profile monitors was studied for transverse measurements on the high brightness ultrarelativistic electron beam at Accelerator Test Facility (ATF) at BNL. The test demonstrated systematic intensity dependent beam image enlargement on YAG monitors, compare to other diagnostics. Possible mechanisms of the effect have been studied. The quantitative examination was performed and compared to the developed phenomenological models. Limitations on the use of YAG:Ce diagnostics are discussed with respect to the high-brightness electron sources.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A High Resolution Electron Beam Pro le Monitor and its Applications

A beam diagnostic to measure transverse pro les of electron beams is described. This pro le monitor uses a cerium-doped yttrium:aluminum:garnet (YAG:Ce) crystal scintillator to produce an image of the transverse beam distribution. The advantage of this material over traditional uorescent screens is that it is formed from a single crystal, and therefore has improved spatial resolution. The resol...

متن کامل

YAG:Ce SCREEN MONITOR USING A GATED CCD CAMERA

Due to its good spatial resolution, the YAG:Ce screen monitor is often used for small beam profile measurement in the Linac and beam transport line. We constructed a high-resolution YAG:Ce screen monitor at KEK-ATF2 for the observation of small size beam. We tested two types of screen, one is ceramic (sintered alumina powder) YAG:Ce and the other is single crystal YAG:Ce. Both screens have 50μm...

متن کامل

Limitations on Measuring a Transverse Profile of Ultra- Dense Electron Beams with Scintillators

As the high-brightness electron beams become denser and reach sub-100 μm sizes, a resolution of the transverse profile diagnostics become an important issue. The applicability of the traditional scintillators as the diagnostics for most generic transverse properties of small dense beams is questionable. Recently, a YAG:Ce single crystal was used successfully, but studies indicated the presence ...

متن کامل

A Beam-profile Monitor for the Bnl Accelerator Test Facility (atf)

A beam-profile monitor has been designed to diagnose the 5-MeV high-brightness electron beam from the rf gun of the BNL Accelerator Test Facility ‘(ATF). The monitor consists of a phosphor screen viewed by a CCD camera. The video images are digitized and stored by a framegrabber and analyzed by an IBM PC-AT to extract the emittance. Details of the hardware configuration are presented, along wit...

متن کامل

A Versatile High Resolution Beam Position Monitor*

A new kind of Cerenkov beam position monitor is described. The counter, though relatively simple and inexpensive, has high sensitivity, introduces a minimal amount of multiple scattering, and is capable of high spatial resolution over a wide range of beam currents 0 Measurements of the position of the SLAC electron beam to an accuracy of I l/2 mm have been made for electron currents from 20 nA ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000