Consensus document on non-invasive ambulatory blood pressure monitoring. The Scientific Committee.
ثبت نشده
چکیده
During a conference devoted to problems of non-invasive ambulatory blood pressure monitoring held in Berlin on March 2 and 3 1990, the following issues were intensively discussed and a consensus was reached on certain aspects. A number of devices are now available which may be considered acceptable in terms of accuracy and reliability, patient acceptability, computer compatibility and cost. To standardize data analysis, day and night blood pressure profiles should be analysed, the daytime period running for 15 +/- 2 h (7.00 a.m. to 10.00 p.m.) and the night-time for 9 +/- 2 h (10.00 p.m. to 7.00 a.m.). Data analysis should provide mean and median systolic, diastolic and mean arterial pressures and heart rates for the daytime, the night-time and the full 24-h period. The results of a meta-analysis of studies on non-invasive ambulatory blood pressure monitoring in healthy and apparently normotensive subjects suggest that a daytime mean blood pressure of greater than or equal to 135/85 mmHg may represent a hypertensive condition (the full 24-h mean may be lower). This may be taken as the provisional cutoff level between a normal and a high daytime blood pressure, pending the results of studies from non-selected general populations including untreated hypertensives. Ambulatory blood pressure monitoring appears to be a better predictor of left ventricular hypertrophy than casual blood pressure measurements are. Since increased left ventricular mass is a strong predictor of an adverse prognosis, ambulatory monitoring may also be more predictive of prognosis than causal readings.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Second international consensus meeting on twenty-four-hour ambulatory blood pressure measurement: consensus and conclusions.
Nun-invasive ambulatory blood pressure monitoring was first developed 30 years ago, and is now evolving from its former role as a somewhat esoteric research tool to becoming a clinically usehl procedure for the evaluation of hypertensive patients. The developing interest in ambulatory blood pressure monitoring in clinical medicine has been reflected in a huge outpouring of publications on the a...
متن کاملEffects of Ramadan fasting on ambulatory blood pressure in hypertensive patients
Background: Previous studies have indicated that Ramadan fasting has beneficial effects on cardiovascular risk factors, specially blood pressure and heart rate. In the present study, the effect of Ramadan fasting on 24-hour ambulatory blood pressure and heart rate has been investigated. Materials and Methods: This prospective observational study was conducted on two groups of individuals. Six p...
متن کاملTissue-Informative Mechanism for Wearable Non-invasive Continuous Blood Pressure Monitoring
Accurate continuous direct measurement of the blood pressure is currently available thru direct invasive methods via intravascular needles, and is mostly limited to use during surgical procedures or in the intensive care unit (ICU). Non-invasive methods that are mostly based on auscultation or cuff oscillometric principles do provide relatively accurate measurement of blood pressure. However, t...
متن کاملThe assessment of agreement between non-invasive, near continuous radial blood pressure measurement and conventional ambulatory blood pressure monitoring during night time sleep
The objective of this study was to compare the blood pressure (BP) measurements during night time sleep of a non-invasive, near-continuous, radial BP instrument to a conventional ambulatory blood pressure monitoring (ABPM) device in a field study setting, in which individuals were not controlled for moving. In order to assess the validity of the radial BP meter in a field setting, we carried ou...
متن کاملComparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study
Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of hypertension. Supplement : official journal of the International Society of Hypertension
دوره 8 6 شماره
صفحات -
تاریخ انتشار 1990