An In Vitro Comparison of Fracture Load of Zirconia Custom Abutments with Internal Connection and Different Angulations and Thicknesses: Part II.

نویسندگان

  • Roya Zandparsa
  • Abdalah Albosefi
چکیده

PURPOSE The purpose of part II of this in vitro study was to compare the fracture load of two-piece zirconia custom abutments with different thicknesses and angulations. MATERIALS AND METHODS Forty zirconia custom abutments were divided into four groups as follows: group A1: 0.7 mm thickness and 0° angulations; group A2: 0.7 mm thickness and 15° angulations; group B1: 1 mm thickness and 0° angulations; group B2: 1 mm thickness and 15° angulations. As in part I, in all groups, implant replicas were mounted in self-cure acrylic jigs to support the abutments. The zirconia custom abutments were engaged in the implant replicas using a manual torque wrench. All jigs were secured and mounted in a metallic vice and subjected to shear stress till failure using a universal testing machine with a 0.5 mm/min crosshead speed with the force transferred to the lingual surface of the zirconia custom abutments 2 mm below the incisal edge. The test specimens used in this study did not include a crown. The universal testing machine was controlled via a computer software system, which also completed the stress-strain diagram and recorded the breaking fracture load. The fracture loads were recorded for comparison among the groups and subjected to statistical analysis (two-way ANOVA and Kolmogorov-Smirnov). RESULTS The mean fracture load of zirconia custom abutments across the groups (A1 to B2) ranged from 432 ± 97 N to 746 ± 275 N. The angulated zirconia custom abutment exhibited the highest fracture load, which was statistically significant (p = 0.045). The thickness of the zirconia custom abutment also had a positive influence on the strength of the specimens (p = 0.005). CONCLUSIONS In this study, the 15° angulated zirconia custom abutments showed the highest fracture load of those investigated. The 1 mm thick zirconia custom abutments also exhibited significantly higher fracture load compared to 0.7 mm abutments. CLINICAL IMPLICATIONS The results of this in vitro study will help dental practitioners with their decision-making process in selecting the type of custom abutment to be used clinically.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bending moments of zirconia and titanium implant abutments supporting all-ceramic crowns after aging.

OBJECTIVES To test the fracture load and fracture patterns of zirconia abutments restored with all-ceramic crowns after fatigue loading, exhibiting internal and external implant-abutment connections as compared to restored and internally fixed titanium abutments. MATERIALS AND METHODS A master abutment was used for the customization of 5 groups of zirconia abutments to a similar shape (test)....

متن کامل

In vitro fatigue and fracture resistance of one- and two-piece CAD/CAM zirconia implant abutments.

PURPOSE All-ceramic abutments are employed increasingly often in implant dentistry for esthetic reasons. In vitro stress testing is required to evaluate the suitability of these constructions, especially in load-bearing posterior regions. The purpose of the study was to assess and compare the fatigue and fracture resistance of one- and two-piece computer-aided design/computer-assisted manufactu...

متن کامل

Assessment of reliability of CAD-CAM tooth-colored implant custom abutments.

STATEMENT OF PROBLEM Information is lacking about the fatigue resistance of computer-aided design and computer-aided manufacturing (CAD-CAM) tooth-colored implant custom abutment materials. PURPOSE The purpose of this in vitro study was to investigate the reliability of different types of CAD-CAM tooth-colored implant custom abutments. MATERIAL AND METHODS Zirconia (Lava Plus), lithium disi...

متن کامل

Evaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro

Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...

متن کامل

Mechanical testing of thin-walled zirconia abutments

UNLABELLED Although the use of zirconia abutments for implant-supported restorations has gained momentum with the increasing demand for esthetics, little informed design rationale has been developed to characterize their fatigue behavior under different clinical scenarios. However, to prevent the zirconia from fracturing, the use of a titanium connection in bi-component aesthetic abutments has ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of prosthodontics : official journal of the American College of Prosthodontists

دوره 23 4  شماره 

صفحات  -

تاریخ انتشار 2014