Standard Trabeculectomy and Ex-PRESS Miniature Glaucoma Shunt: A Comparative Study and Literature Review

نویسندگان

  • Elad Moisseiev
  • Eran Zunz
  • Rotem Tzur
  • Shimon Kurtz
  • Gabi Shemesh
چکیده

PURPOSE The aim of this study was to compare the efficacy and safety between standard trabeculectomy and the Ex-PRESS shunt implantation. METHODS A retrospective review of the records of 100 eyes of 100 patients who underwent trabeculectomy or Ex-PRESS shunt implantation between July 2010 and June 2012 was conducted. Of these, 61 (61%) eyes underwent trabeculectomy and 39 (39%) eyes underwent Ex-PRESS shunt implantation. Demographic information, glaucoma type, surgical details, preoperative, and postoperative data including intraocular pressure (IOP), number of medications, reoperation, and occurrence of any complications were recorded. RESULTS No differences in IOP reduction or number of postoperative IOP-lowering medications were demonstrated between the 2 procedures. Success rates were 86.9% for trabeculectomy and 84.6% for Ex-PRESS shunt. Rates of failure and hypotony were not significantly different between the groups. No parameter was correlated with success or failure of any procedure. CONCLUSIONS Standard trabeculectomy and Ex-PRESS shunt have similar efficacy and safety profiles. As the Ex-PRESS shunt is considerably more expensive, its use may be unjustified, especially as a primary procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Surgical Treatment of Neovascular Glaucoma with Ex-PRESS P-50 Miniature Glaucoma Shunt

Surgical treatment for neovascular glaucoma has evolved from cyclodestructive procedures to full-thickness filtration surgery, to trabeculectomy with antifibrosis drugs and glaucoma drainage implant surgery. The choice of a surgical approach may be influenced by several factors, including the stage of the disease. Many surgeons favor drainage implants when the disease is more advanced or when s...

متن کامل

[Postoperative outcomes after combined glaucoma surgery. Comparison of ex-press miniature implant with standard trabeculectomy].

PURPOSE To evaluate postoperative outcomes and success after combined phacoemulsification and glaucoma surgery with Ex-PRESS miniature implant compared with combined surgery with standard trabeculectomy. METHODS In this prospective series of 40 consecutive eyes we compared 20 eyes in 17 patients treated with combined phacoemulsification and glaucoma filtering surgery with the Ex-PRESS miniatu...

متن کامل

Combined procedure of phacoemulsification and implantation of Ex-PRESS miniature glaucoma shunt.

Glaucoma patients not responding to maximum medical therapy with coexistent cataract are candidates for combined cataract and glaucoma therapy. There are different therapy models. The choice of therapy depends on numerous patient and surgeon related factors. Ex-PRESS mini glaucoma shunt is a modified trabeculectomy and can be combined with cataract surgery when indicated. In this paper we prese...

متن کامل

A comparison of the Ex-PRESS™ mini glaucoma shunt with standard trabeculectomy in the surgical treatment of glaucoma.

BACKGROUND AND OBJECTIVE To compare the success and complication rates of patients with glaucoma who had an Ex-PRESS mini glaucoma shunt device implantation (Optonol, Ltd., Neve Ilan, Israel) to those who had conventional trabeculectomy. PATIENTS AND METHODS The records of 76 eyes of 69 consecutive subjects who had Ex-PRESS implants and 77 eyes of 65 consecutive controls who had trabeculectom...

متن کامل

[Tacrolimus in the treatment of atopic kerato-conjunctivitis].

1. Abraham N, Yoseff G, Michael B, Yoram E. Biocompatibility of the Ex-PRESS® miniature glaucoma drainage implant. J Glaucoma. 2003;12:275–80. 2. Gallego-Pinazo R, López-Sánchez E, Marín-Montiel J. Resultados postquirúrgicos en la cirugía combinada de glaucoma. Comparación del implante Ex-PRESS® con la trabeculectomía. Arch Soc Esp Oftalmol. 2009;84: 293–8. 3. Francis BA, Singh K, Lin SC, Hodap...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 24  شماره 

صفحات  -

تاریخ انتشار 2015