Occipitocervical fusion.

نویسندگان

  • Ben J Garrido
  • Rick C Sasso
چکیده

The evolution of occipitocervical fixation and new rigid universal screw-rod construct technology has allowed secure anchorage at each level of the occipitocervical junction with the elimination of rigid external orthoses. Rigid occipitocervical instrumentation constructs have achieved higher fusion rates and less postoperative immobilization-associated complications. Outcomes have improved compared with former nonrigid instrumentation techniques; however, with advances of rigid occipitocervical stabilization capability have come new challenges, risks, and operative techniques. A thorough understanding of the relevant cervical bony and soft tissue anatomy is essential for safe implantation and a successful outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of occipitocervical neutral position using lateral radiographs

BACKGROUND Intraoperative assessment of neutral occipitocervical balance during a fusion procedure is challenging. We designed this study to introduce a more comprehensive method of evaluating the occipitocervical neutral position using lateral radiographs. METHODS One hundred neutral lateral cervical spine radiographs interpreted as normal were studied. Cervical spine radiographs were perfor...

متن کامل

The Use of Bone Morphogenetic Protein in Pediatric Cervical Spine Fusion Surgery: Case Reports and Review of the Literature

Study Design Case report. Objective There is a paucity of literature describing the use of bone graft substitutes to achieve fusion in the pediatric cervical spine. The outcomes and complications involving the off-label use of bone morphogenetic protein (BMP)-2 in the pediatric cervical spine are not clearly defined. The purpose of this article is to report successful fusion without complicatio...

متن کامل

Use of screw-rod system in occipitocervical fixation.

BACKGROUND This study retrospectively reviewed 9 patients who underwent occipitocervical fixation with a newly developed screw-rod fixation system between April 2004 and November 2005. The objective was to evaluate the clinical result of occipitocervical fixation with the screw-rod fixation system, including symptom relief, fusion rate and complications. METHODS All 9 patients received occipi...

متن کامل

Posterior occipito cervical decompression with fixation and fusion in Cranio vertebral junction compression

Objective To find out the clinical outcome of posterior decompression with occipitocervical fixation and fusion in patients with Craniovertebral junction instability. Methods Eighty consecutive patients of cranio vertebral junction (CVJ) compression were treated in the department of neurosurgery, Jinnah Postgraduate Medical Centre (JPMC), Karachi over a period of 05 years from 1st January 201...

متن کامل

Effect of occipitocervical fusion with screw-rod system for upper cervical spine tumor

BACKGROUND Craniospinal junction tumors are rare but severe lesions. Surgical stabilization has been established to be an ideal treatment for upper cervical tumor pathology. The purpose of this study was to evaluate the effect of a screw-rod system for occipitocervical fusion. METHODS A total of 24 cases with C1 and C2 cervical tumor underwent occipitocervical fusion with Vertex screw-rod int...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Orthopedic clinics of North America

دوره 43 1  شماره 

صفحات  -

تاریخ انتشار 2012