Bendable vs. angulated dental implants: consideration of elastic and plastic material properties based on experimental implant material data and FEA.
نویسندگان
چکیده
AIM Bendable and angulated single-piece implants are used alternatively to screwable abutments in two-piece dental implant designs. Though used frequently, data on the stress distribution within such implants are not available and the question whether the bending contributes to fracture resistance has not been addressed. METHODS We used the method of finite element to identify von Mises stresses and maximum stresses in bent and non-bent but angulated implants. Implants with one (e.g. applicable to screw designs) or two (applicable to basal implants) bending areas were the variables under investigation. RESULTS For bends up to 13 degrees we discovered that if there is only one bend, the maximum stress is in the bent area. If two bends are made in two different bending areas, the maximum stresses are distributed between the two and, if either one of the bent areas is machined, there are no residual stresses within the implant body in this area. The maximum stresses are always located near the base-plates. The absolute value of the maximum stress is higher because no residual stresses are available to compensate stresses that stem from loading. CONCLUSION Assuming that all other parameters are equal, bendable (basal) implants show a more even stress distribution along the vertical implant region than identically shaped implants with a machine-angulated area. Bendable basal implants therefore probably resist masticatory forces better than pre-angulated, machined implants, and unbent implants which provide a thin region in the vertical implant area.
منابع مشابه
Effect of Abutment Angulation and Material on Stress and Strain Distributions in Premaxillary Bone: A Three-Dimensional Finite Element Analysis
Background and Aim: Dental implants with angled abutments are often inserted in the anterior maxillary region due to the status of the residual ridge and aesthetic considerations. The purpose of this study was to assess stress and strain distributions in the premaxillary bone around dental implants by means of finite element analysis (FEA). Materials and Methods: Four three-dimensional (3D) fi...
متن کاملتعیین توزیع تنش و کرنش استخوان اطراف ایمپلنت در طرح All-on-4 به روش آنالیز اجزای محدود
Background and Aims: The All-on-4 design with its significant advantages is an appropriate model in reconstruction of edentulous mandible. Evaluation of stress and strain distribution in this model is necessary for better judgment. The purpose of this FEA study was to measure stress and strain distribution on peri-implant bone in All-on-4 design in edentulous mandible. Materials and Methods: Th...
متن کاملExperimental Investigation of FGM Dental Implant Properties Made from Ti/HA Composite
Although titanium/hydroxyapatite composite is an attractive material for dental implants, it would be more useful if it could be produced as a functionally graded material (FGM). In this paper, microstructure and microhardness of a five-layer titanium/hydroxyapatite functionally graded material has been investigated. First, titanium and hydroxyapatite (HA) powders were mixed with the Ti to HA v...
متن کاملEffect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis
This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in...
متن کاملElastic-Plastic Transition of Pressurized Functionally Graded Orthotropic Cylinder using Seth’s Transition Theory
In this paper the radial deformation and the corresponding stresses in a functionally graded orthotropic hollow cylinder with the variation in thickness and density according to power law and rotating about its axis under pressure is investigated by using Seth's transition theory. The material of the cylinder is assumed to be non-homogeneous and orthotropic. This theory helps to achieve better ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia
دوره 152 2 شماره
صفحات -
تاریخ انتشار 2008