988 Energy Conversion Efficiency in Human Left Ventricle
نویسندگان
چکیده
Background. Left ventricular mechanical efficiency is one of the most important measures of left ventricular pump performance. Several clinical studies, however, have shown that mechanical efficiency does not fall substantially as the heart fails. To clarify the insensitivity of mechanical efficiency to the change in pump performance, we analyzed human left ventricular mechanical efficiency, applying the concept of left ventricular systolic pressure-volume area (PVA). Methods and Results. PVA correlates linearly with myocardial oxygen consumption per beat (MVo2): MVo2=a * PVA+b, and represents the total mechanical energy of contraction. We determined MVo2-PVA relation and external work in 11 patients with different contractile states. We also calculated the energy transfer from MVo2 to PVA (PVA/MVo2 efficiency), that from PVA to external work (work efficiency), and mechanical efficiency (external work/MVo2). Left ventricular pressure-volume loops were constructed by plotting the instantaneous left ventricular pressure against the left ventricular volume at baseline and during pressure loading. The contractile properties of the ventricle were defined by the slope of the end-systolic pressure-volume relation (Ees). Pressure elevation raised external work by 41.4%, PVA by 71.2%, and MVo2 by 54.5%. These changes were associated with a decrease in work efficiency and an increase in PVA/MVo2 efficiency. The opposite directional changes in these two efficiencies rendered the mechanical efficiency constant. The slope, a, of the relation between MVo2 and PVA was relatively constant (2.46±0.33) over the range of 0.8-8.8 mm Hg/ml of Ees, but the oxygen axis intercept, b, tended to decrease with the reduction in Ees. PVA/MVo2 efficiency correlated inversely (r= -0.66, p <0.05) with Ees, whereas work efficiency correlated linearly with Ees (r=0.91, p<0.01). Conclusions. Mechanical efficiency is not appreciably affected by changes in loading and inotropic conditions as long as the left ventricular contractility is not severely depressed. (Circulation 1992;85:988-996)
منابع مشابه
Energy conversion efficiency in human left ventricle.
BACKGROUND Left ventricular mechanical efficiency is one of the most important measures of left ventricular pump performance. Several clinical studies, however, have shown that mechanical efficiency does not fall substantially as the heart fails. To clarify the insensitivity of mechanical efficiency to the change in pump performance, we analyzed human left ventricular mechanical efficiency, app...
متن کاملEffect of exercise on left ventricular mechanical efficiency in conscious dogs.
BACKGROUND We studied the effect of exercise (7.2 to 8.0 km/h) on the efficiency of the conversion of metabolic energy to external work or stroke work (SW) by the left ventricle (LV). METHODS AND RESULTS Energy use was calculated from LV myocardial oxygen consumption per beat (MVO2). LV volume was calculated from orthogonal dimensions and coronary flow measured with ultrasonic flow probes. Th...
متن کاملMechanical matching of the left ventricle with the arterial system in exercising dogs.
We investigated how changes in ventricular contractility and arterial properties associated with exercise influence the energy transmission from the left ventricle to the arterial system. On six chronically instrumented dogs preconditioned to run on a treadmill, we imposed exercise loads of various degrees by altering the speed and slope of the treadmill (up to 7 km/hr and 20% slope). We evalua...
متن کاملEchocardiographic Assessment of Left Ventricle Torsion by Tissue Doppler and Velocity Vector Imaging
Introduction Left ventricular (LV) twist is believed to store potential energy and plays an important role in generating diastolic suction. Recent advances in echocardiography techniques have allowed quantification of LV twist. The aim of the present study was to compare LV twist and torsion in healthy human subjects determined by velocity vector imaging (VVI) and tissue Doppler imaging (TDI) a...
متن کاملMechanical Efficiency in Conscious Dogs
Background We studied the effect of exercise (7.2 to 8.0 km/h) on the efficiency of the conversion of metabolic energy to external work or stroke work (SW) by the left ventricle (LV). Methods and Results Energy use was calculated from LV myocardial oxygen consumption per beat (MVo2). LV volume was calculated from orthogonal dimensions and coronary flow measured with ultrasonic flow probes. The ...
متن کامل